fixed negative ac and dc solar values
This commit is contained in:
1 parent
6412630c85
commit
4d27f108fa
1 file changed
+7
-7
@@ -20,11 +20,11 @@ class EP600(ProtocolV2Device):
|
||||
|
||||
# DC Solar
|
||||
self.struct.add_uint_field("pv_input_power1", 1212)
|
||||
self.struct.add_uint_field("pv_input_voltage1", 1213)
|
||||
self.struct.add_uint_field("pv_input_current1", 1214)
|
||||
self.struct.add_decimal_field("pv_input_voltage1", 1213, 1)
|
||||
self.struct.add_decimal_field("pv_input_current1", 1214, 1)
|
||||
self.struct.add_uint_field("pv_input_power2", 1220)
|
||||
self.struct.add_uint_field("pv_input_voltage2", 1221)
|
||||
self.struct.add_uint_field("pv_input_current2", 1222)
|
||||
self.struct.add_decimal_field("pv_input_voltage2", 1221, 1)
|
||||
self.struct.add_decimal_field("pv_input_current2", 1222, 1)
|
||||
|
||||
# ADL400 Smart Meter for AC Solar
|
||||
self.struct.add_uint_field("adl400_ac_input_power_phase1", 1228)
|
||||
@@ -52,9 +52,9 @@ class EP600(ProtocolV2Device):
|
||||
|
||||
# EP600 AC Output
|
||||
self.struct.add_decimal_field("ac_output_frequency", 1500, 1)
|
||||
self.struct.add_uint_field("ac_output_power_phase1", 1510)
|
||||
self.struct.add_uint_field("ac_output_power_phase2", 1517)
|
||||
self.struct.add_uint_field("ac_output_power_phase3", 1524)
|
||||
self.struct.add_int_field("ac_output_power_phase1", 1510)
|
||||
self.struct.add_int_field("ac_output_power_phase2", 1517)
|
||||
self.struct.add_int_field("ac_output_power_phase3", 1524)
|
||||
self.struct.add_decimal_field("ac_output_voltage_phase1", 1511, 1)
|
||||
self.struct.add_decimal_field("ac_output_voltage_phase2", 1518, 1)
|
||||
self.struct.add_decimal_field("ac_output_voltage_phase3", 1525, 1)
|
||||
|
||||
Reference in new issue