Merge pull request #119 from kvanonavk/main

AC180P Advanced Integration
This commit is contained in:
Patrick762 authored and GitHub committed 2024-07-19 16:17:16 +02:00
commit 6f9afedfdb
4 files changed
+60 -2

No files matched your search

+1 -1
View File
@@ -20,7 +20,7 @@ After the installation, you can use this button to install the integration:
- AC70 (basic data) - AC70 (basic data)
- AC70P (untested) - AC70P (untested)
- AC180 (basic data) - AC180 (basic data)
- AC180P (basic data) - AC180P (tested)
- AC200L (untested) - AC200L (untested)
- AC200M - AC200M
- AC300 (tested) - AC300 (tested)
@@ -1,8 +1,52 @@
"""AC180P fields.""" """AC180P fields."""
from ..base_devices.ProtocolV2Device import ProtocolV2Device from typing import List
from ..field_enums import ChargingMode
from ..utils.commands import ReadHoldingRegisters
from ..base_devices.ProtocolV2Device import ProtocolV2Device
class AC180P(ProtocolV2Device): class AC180P(ProtocolV2Device):
def __init__(self, address: str, sn: str): def __init__(self, address: str, sn: str):
super().__init__(address, "AC180P", sn) super().__init__(address, "AC180P", sn)
# Power IO
self.struct.add_uint_field('dc_output_power', 140)
self.struct.add_uint_field('ac_output_power', 142)
self.struct.add_uint_field('dc_input_power', 144)
self.struct.add_uint_field('ac_input_power', 146)
# Input Details (1100 - 1300)
self.struct.add_decimal_field('ac_input_voltage', 1314, 1)
# Controls (2000)
self.struct.add_bool_field('ac_output_on_switch', 2011)
self.struct.add_bool_field('dc_output_on_switch', 2012)
self.struct.add_bool_field('silent_charging_on', 2020) # to be able to choose between normal and silent charging modes
self.struct.add_enum_field('charging_mode', 2020, ChargingMode) # can't be set from HA, custom switch needed
self.struct.add_bool_field('power_lifting_on', 2021)
# Controls (2200)
self.struct.add_bool_field('grid_enhancement_mode_on', 2225)
@property
def polling_commands(self) -> List[ReadHoldingRegisters]:
return super().polling_commands + [
ReadHoldingRegisters(140, 1),
ReadHoldingRegisters(142, 1),
ReadHoldingRegisters(144, 1),
ReadHoldingRegisters(146, 1),
ReadHoldingRegisters(1314, 1),
ReadHoldingRegisters(2011, 1),
ReadHoldingRegisters(2012, 1),
ReadHoldingRegisters(2020, 1),
ReadHoldingRegisters(2021, 1),
ReadHoldingRegisters(2225, 1),
]
@property
def writable_ranges(self) -> List[range]:
return super().writable_ranges + [
range(2000, 2022),
range(2200, 2226)
]
@@ -316,6 +316,16 @@ FIELD_ATTRIBUTES: dict[str, FieldAttributes] = {
setter=True, setter=True,
name="Power Lifting", name="Power Lifting",
), ),
"grid_enhancement_mode_on": FieldAttributes(
type=FieldType.BOOL,
setter=True,
name="Grid Enhancement Mode",
),
"silent_charging_on": FieldAttributes(
type=FieldType.BOOL,
setter=True,
name="Silent Charging",
),
} }
+4
View File
@@ -23,6 +23,7 @@ SUPPORTED_MODELS = [
"EP500P", "EP500P",
"EP600", "EP600",
"EP760", "EP760",
"AC180P",
] ]
CONTROL_FIELDS = [ CONTROL_FIELDS = [
@@ -31,6 +32,8 @@ CONTROL_FIELDS = [
"power_off", "power_off",
"eco_on", "eco_on",
"power_lifting_on", "power_lifting_on",
"grid_enhancement_mode_on",
"silent_charging_on",
] ]
DIAGNOSTIC_FIELDS = [ DIAGNOSTIC_FIELDS = [
@@ -45,4 +48,5 @@ DIAGNOSTIC_FIELDS = [
"total_ac_consumption", "total_ac_consumption",
"total_grid_consumption", "total_grid_consumption",
"total_grid_feed", "total_grid_feed",
"ac_input_voltage",
] ]