@@ -104,4 +104,76 @@ ADDITIONAL_DEVICE_FIELDS = {
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_input_voltage_phase1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Input Voltage Phase 1",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_input_voltage_phase2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Input Voltage Phase 2",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_input_voltage_phase3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Input Voltage Phase 3",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_voltage_phase1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Voltage Phase 1",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_voltage_phase2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Voltage Phase 2",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_voltage_phase3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Voltage Phase 3",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
}
|
||||
@@ -45,6 +45,12 @@ class DummyDevice(BluettiDevice):
|
||||
self.struct.add_decimal_field("adl400_ac_input_voltage_phase1", 1229, 1)
|
||||
self.struct.add_decimal_field("adl400_ac_input_voltage_phase2", 1237, 1)
|
||||
self.struct.add_decimal_field("adl400_ac_input_voltage_phase3", 1245, 1)
|
||||
self.struct.add_decimal_field("ac_input_voltage_phase1", 1314, 1)
|
||||
self.struct.add_decimal_field("ac_input_voltage_phase2", 1320, 1)
|
||||
self.struct.add_decimal_field("ac_input_voltage_phase3", 1326, 1)
|
||||
self.struct.add_decimal_field("ac_output_voltage_phase1", 1511, 1)
|
||||
self.struct.add_decimal_field("ac_output_voltage_phase2", 1518, 1)
|
||||
self.struct.add_decimal_field("ac_output_voltage_phase3", 1525, 1)
|
||||
|
||||
super().__init__(device.address, device.type, device.sn)
|
||||
self._parent = device
|
||||
@@ -55,12 +61,13 @@ class DummyDevice(BluettiDevice):
|
||||
return [
|
||||
ReadHoldingRegisters(100, 62),
|
||||
ReadHoldingRegisters(1229, 19),
|
||||
ReadHoldingRegisters(1314, 13),
|
||||
ReadHoldingRegisters(1511, 15),
|
||||
ReadHoldingRegisters(2022, 6),
|
||||
ReadHoldingRegisters(2213, 4),
|
||||
# Battery
|
||||
ReadHoldingRegisters(6101, 7),
|
||||
ReadHoldingRegisters(6175, 11),
|
||||
# current limit for reading ReadHoldingRegisters(0x2F2F, 1),
|
||||
]
|
||||
|
||||
return self._parent.polling_commands
|
||||
|
||||