replaced bluetti_mqtt imports with local lib
This commit is contained in:
1 parent
18825f9062
commit
c45994a9a6
5 files changed
+29
-562
No files matched your search
@@ -2,8 +2,6 @@
|
||||
|
||||
import re
|
||||
|
||||
from bluetti_mqtt.mqtt_client import MqttFieldConfig, MqttFieldType
|
||||
|
||||
DOMAIN = "bluetti_bt"
|
||||
MANUFACTURER = "Bluetti"
|
||||
|
||||
@@ -44,508 +42,3 @@ DIAGNOSTIC_FIELDS = [
|
||||
"safety_module_version",
|
||||
"high_voltage_module_version",
|
||||
]
|
||||
|
||||
ADDITIONAL_DEVICE_FIELDS = {
|
||||
"max_ac_input_power": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Max AC Input Power per Phase",
|
||||
},
|
||||
),
|
||||
"max_ac_input_current": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Max AC Input Current per Phase",
|
||||
},
|
||||
),
|
||||
"max_ac_output_power": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Max AC Output Power per Phase",
|
||||
},
|
||||
),
|
||||
"max_ac_output_current": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Max AC Output Current per Phase",
|
||||
},
|
||||
),
|
||||
"bcu_version": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={"name": "BCU Version"},
|
||||
),
|
||||
"safety_module_version": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={"name": "Safety Module Version"},
|
||||
),
|
||||
"high_voltage_module_version": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={"name": "High Voltage Safety Module Version"},
|
||||
),
|
||||
'pv_input_power1': MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Solar Input Power 1",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
'pv_input_voltage1': MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Solar Input Voltage 1",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
'pv_input_current1': MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Solar Input Current 1",
|
||||
"unit_of_measurement": "A",
|
||||
"device_class": "current",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
'pv_input_power2': MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Solar Input Power 2",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
'pv_input_voltage2': MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Solar Input Voltage 2",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
'pv_input_current2': MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Solar Input Current 2",
|
||||
"unit_of_measurement": "A",
|
||||
"device_class": "current",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"adl400_ac_input_power_phase1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "ADL400 AC Input Power Phase 1",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"adl400_ac_input_power_phase2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "ADL400 AC Input Power Phase 2",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"adl400_ac_input_power_phase3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "ADL400 AC Input Power Phase 3",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"adl400_ac_input_voltage_phase1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "ADL400 AC Input Voltage Phase 1",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"adl400_ac_input_voltage_phase2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "ADL400 AC Input Voltage Phase 2",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"adl400_ac_input_voltage_phase3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "ADL400 AC Input Voltage Phase 3",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"grid_input_voltage_phase1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Grid Input Voltage Phase 1",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"grid_input_voltage_phase2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Grid Input Voltage Phase 2",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"grid_input_voltage_phase3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Grid Input Voltage Phase 3",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"grid_input_current_phase1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Grid Input Current Phase 1",
|
||||
"unit_of_measurement": "A",
|
||||
"device_class": "current",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"grid_input_current_phase2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Grid Input Current Phase 2",
|
||||
"unit_of_measurement": "A",
|
||||
"device_class": "current",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"grid_input_current_phase3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Grid Input Current Phase 3",
|
||||
"unit_of_measurement": "A",
|
||||
"device_class": "current",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"grid_input_power_phase1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Grid Input Power Phase 1",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"grid_input_power_phase2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Grid Input Power Phase 2",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"grid_input_power_phase3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Grid Input Power Phase 3",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_frequency": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Frequency",
|
||||
"unit_of_measurement": "Hz",
|
||||
"device_class": "frequency",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_voltage_phase1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Voltage Phase 1",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_voltage_phase2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Voltage Phase 2",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_voltage_phase3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Voltage Phase 3",
|
||||
"unit_of_measurement": "V",
|
||||
"device_class": "voltage",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_power_phase1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Power Phase 1",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_power_phase2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Power Phase 2",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_power_phase3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Power Phase 3",
|
||||
"unit_of_measurement": "W",
|
||||
"device_class": "power",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_current_phase1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Current Phase 1",
|
||||
"unit_of_measurement": "A",
|
||||
"device_class": "current",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_current_phase2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Current Phase 2",
|
||||
"unit_of_measurement": "A",
|
||||
"device_class": "current",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"ac_output_current_phase3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "AC Output Current Phase 3",
|
||||
"unit_of_measurement": "A",
|
||||
"device_class": "current",
|
||||
"state_class": "measurement",
|
||||
"force_update": True,
|
||||
},
|
||||
),
|
||||
"testing0": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Register Testing 0",
|
||||
},
|
||||
),
|
||||
"testing1": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Register Testing 1",
|
||||
},
|
||||
),
|
||||
"testing2": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Register Testing 2",
|
||||
},
|
||||
),
|
||||
"testing3": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Register Testing 3",
|
||||
},
|
||||
),
|
||||
"testing4": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Register Testing 4",
|
||||
},
|
||||
),
|
||||
"testing5": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Register Testing 5",
|
||||
},
|
||||
),
|
||||
"testing6": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Register Testing 6",
|
||||
},
|
||||
),
|
||||
"testing7": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Register Testing 7",
|
||||
},
|
||||
),
|
||||
"testing8": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Register Testing 8",
|
||||
},
|
||||
),
|
||||
"testing9": MqttFieldConfig(
|
||||
type=MqttFieldType.NUMERIC,
|
||||
setter=False,
|
||||
advanced=False,
|
||||
home_assistant_extra={
|
||||
"name": "Register Testing 9",
|
||||
},
|
||||
),
|
||||
}
|
||||
Reference in new issue