added ep600
This commit is contained in:
1 parent
03b11a69d5
commit
d8c61e1ebe
2 files changed
+212
-5
No files matched your search
@@ -0,0 +1,98 @@
|
||||
"""EP600 fields."""
|
||||
|
||||
from typing import List
|
||||
|
||||
from ..utils.commands import ReadHoldingRegisters
|
||||
from ..base_devices.ProtocolV2Device import ProtocolV2Device
|
||||
|
||||
|
||||
class EP600(ProtocolV2Device):
|
||||
def __init__(self, address: str, sn: str):
|
||||
super().__init__(address, "EP600", sn)
|
||||
|
||||
# Details
|
||||
self.struct.add_uint_field("battery_range_start", 2022)
|
||||
self.struct.add_uint_field("battery_range_end", 2023)
|
||||
self.struct.add_uint_field("max_ac_input_power", 2213)
|
||||
self.struct.add_uint_field("max_ac_input_current", 2214)
|
||||
self.struct.add_uint_field("max_ac_output_power", 2215)
|
||||
self.struct.add_uint_field("max_ac_output_current", 2216)
|
||||
|
||||
# DC Solar
|
||||
self.struct.add_uint_field("pv_input_power1", 1212)
|
||||
self.struct.add_uint_field("pv_input_voltage1", 1213)
|
||||
self.struct.add_uint_field("pv_input_current1", 1214)
|
||||
self.struct.add_uint_field("pv_input_power2", 1220)
|
||||
self.struct.add_uint_field("pv_input_voltage2", 1221)
|
||||
self.struct.add_uint_field("pv_input_current2", 1222)
|
||||
|
||||
# ADL400 Smart Meter for AC Solar
|
||||
self.struct.add_uint_field("adl400_ac_input_power_phase1", 1228)
|
||||
self.struct.add_uint_field("adl400_ac_input_power_phase2", 1236)
|
||||
self.struct.add_uint_field("adl400_ac_input_power_phase3", 1244)
|
||||
self.struct.add_decimal_field("adl400_ac_input_voltage_phase1", 1229, 1)
|
||||
self.struct.add_decimal_field("adl400_ac_input_voltage_phase2", 1237, 1)
|
||||
self.struct.add_decimal_field("adl400_ac_input_voltage_phase3", 1245, 1)
|
||||
# Testing required
|
||||
self.struct.add_uint_field("adl400_ac_input_current_phase1", 1230)
|
||||
self.struct.add_uint_field("adl400_ac_input_current_phase2", 1238)
|
||||
self.struct.add_uint_field("adl400_ac_input_current_phase3", 1246)
|
||||
|
||||
# Grid Input
|
||||
self.struct.add_decimal_field("grid_frequency", 1300, 1)
|
||||
self.struct.add_uint_field("grid_power_phase1", 1313)
|
||||
self.struct.add_uint_field("grid_power_phase2", 1319)
|
||||
self.struct.add_uint_field("grid_power_phase3", 1325)
|
||||
self.struct.add_decimal_field("grid_voltage_phase1", 1314, 1)
|
||||
self.struct.add_decimal_field("grid_voltage_phase2", 1320, 1)
|
||||
self.struct.add_decimal_field("grid_voltage_phase3", 1326, 1)
|
||||
self.struct.add_decimal_field("grid_current_phase1", 1315, 1)
|
||||
self.struct.add_decimal_field("grid_current_phase2", 1321, 1)
|
||||
self.struct.add_decimal_field("grid_current_phase3", 1327, 1)
|
||||
|
||||
# EP600 AC Output
|
||||
self.struct.add_decimal_field("ac_output_frequency", 1500, 1)
|
||||
self.struct.add_uint_field("ac_output_power_phase1", 1510)
|
||||
self.struct.add_uint_field("ac_output_power_phase2", 1517)
|
||||
self.struct.add_uint_field("ac_output_power_phase3", 1524)
|
||||
self.struct.add_decimal_field("ac_output_voltage_phase1", 1511, 1)
|
||||
self.struct.add_decimal_field("ac_output_voltage_phase2", 1518, 1)
|
||||
self.struct.add_decimal_field("ac_output_voltage_phase3", 1525, 1)
|
||||
self.struct.add_decimal_field("ac_output_current_phase1", 1512, 1)
|
||||
self.struct.add_decimal_field("ac_output_current_phase2", 1519, 1)
|
||||
self.struct.add_decimal_field("ac_output_current_phase3", 1526, 1)
|
||||
|
||||
# Statistics
|
||||
self.struct.add_decimal_field(
|
||||
"total_ac_consumption", 152, 1
|
||||
) # Load consumption
|
||||
self.struct.add_decimal_field(
|
||||
"total_grid_consumption", 156, 1
|
||||
) # Grid consumption stats
|
||||
self.struct.add_decimal_field("total_grid_feed", 158, 1)
|
||||
|
||||
# Battery packs
|
||||
self.struct.add_swap_string_field("battery_type", 6101, 6) # internal
|
||||
self.struct.add_sn_field("battery_serial_number", 6107) # internal
|
||||
self.struct.add_version_field("bcu_version", 6175) # internal
|
||||
self.struct.add_version_field("bmu_version", 6178) # internal
|
||||
self.struct.add_version_field("safety_module_version", 6181) # internal
|
||||
self.struct.add_version_field("high_voltage_module_version", 6184) # internal
|
||||
|
||||
# @property
|
||||
# def pack_num_max(self):
|
||||
# return 16
|
||||
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(2022, 2),
|
||||
ReadHoldingRegisters(2213, 5),
|
||||
]
|
||||
|
||||
# @property
|
||||
# def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
# return super().pack_polling_commands + [
|
||||
# ReadHoldingRegisters(6101, 10),
|
||||
# ReadHoldingRegisters(6175, 12),
|
||||
# ]
|
||||
@@ -57,6 +57,14 @@ class CurrentFieldAttributes(FieldAttributes):
|
||||
state_class = "measurement"
|
||||
|
||||
|
||||
@dataclass
|
||||
class EnergyFieldAttributes(FieldAttributes):
|
||||
type = FieldType.NUMERIC
|
||||
unit_of_measurement = "kWh"
|
||||
device_class = "energy"
|
||||
state_class = "total_increasing"
|
||||
|
||||
|
||||
@dataclass
|
||||
class FrequencyFieldAttributes(FieldAttributes):
|
||||
type = (FieldType.NUMERIC,)
|
||||
@@ -85,12 +93,8 @@ FIELD_ATTRIBUTES = {
|
||||
"dc_output_power": PowerFieldAttributes(
|
||||
name="DC Output Power",
|
||||
),
|
||||
"power_generation": FieldAttributes(
|
||||
type=FieldType.NUMERIC,
|
||||
"power_generation": EnergyFieldAttributes(
|
||||
name="Total Power Generation",
|
||||
unit_of_measurement="kWh",
|
||||
device_class="energy",
|
||||
state_class="total_increasing",
|
||||
),
|
||||
"total_battery_percent": FieldAttributes(
|
||||
type=FieldType.NUMERIC,
|
||||
@@ -162,6 +166,111 @@ FIELD_ATTRIBUTES = {
|
||||
"internal_dc_input_current": CurrentFieldAttributes(
|
||||
name="Internal DC Input Current",
|
||||
),
|
||||
"pv_input_power1": PowerFieldAttributes(
|
||||
name="Solar Input Power 1",
|
||||
),
|
||||
"pv_input_power2": PowerFieldAttributes(
|
||||
name="Solar Input Power 2",
|
||||
),
|
||||
"pv_input_voltage1": VoltageFieldAttributes(
|
||||
name="Solar Input Voltage 1",
|
||||
),
|
||||
"pv_input_voltage2": VoltageFieldAttributes(
|
||||
name="Solar Input Voltage 2",
|
||||
),
|
||||
"pv_input_current1": CurrentFieldAttributes(
|
||||
name="Solar Input Current 1",
|
||||
),
|
||||
"pv_input_current2": CurrentFieldAttributes(
|
||||
name="Solar Input Current 2",
|
||||
),
|
||||
"adl400_ac_input_power_phase1": PowerFieldAttributes(
|
||||
name="AC Solar Input Power Phase 1"
|
||||
),
|
||||
"adl400_ac_input_power_phase2": PowerFieldAttributes(
|
||||
name="AC Solar Input Power Phase 2"
|
||||
),
|
||||
"adl400_ac_input_power_phase3": PowerFieldAttributes(
|
||||
name="AC Solar Input Power Phase 3"
|
||||
),
|
||||
"adl400_ac_input_voltage_phase1": VoltageFieldAttributes(
|
||||
name="AC Solar Input Voltage Phase 1",
|
||||
),
|
||||
"adl400_ac_input_voltage_phase2": VoltageFieldAttributes(
|
||||
name="AC Solar Input Voltage Phase 2",
|
||||
),
|
||||
"adl400_ac_input_voltage_phase3": VoltageFieldAttributes(
|
||||
name="AC Solar Input Voltage Phase 3",
|
||||
),
|
||||
"adl400_ac_input_current_phase1": CurrentFieldAttributes(
|
||||
name="AC Solar Input Current Phase 1",
|
||||
),
|
||||
"adl400_ac_input_current_phase2": CurrentFieldAttributes(
|
||||
name="AC Solar Input Current Phase 2",
|
||||
),
|
||||
"adl400_ac_input_current_phase3": CurrentFieldAttributes(
|
||||
name="AC Solar Input Current Phase 3",
|
||||
),
|
||||
"grid_frequency": FrequencyFieldAttributes(
|
||||
name="Grid Frequency",
|
||||
),
|
||||
"grid_power_phase1": PowerFieldAttributes(
|
||||
name="Grid Power Phase 1",
|
||||
),
|
||||
"grid_power_phase2": PowerFieldAttributes(
|
||||
name="Grid Power Phase 2",
|
||||
),
|
||||
"grid_power_phase3": PowerFieldAttributes(
|
||||
name="Grid Power Phase 3",
|
||||
),
|
||||
"grid_voltage_phase1": VoltageFieldAttributes(
|
||||
name="Grid Voltage Phase 1",
|
||||
),
|
||||
"grid_voltage_phase2": VoltageFieldAttributes(
|
||||
name="Grid Voltage Phase 2",
|
||||
),
|
||||
"grid_voltage_phase3": VoltageFieldAttributes(
|
||||
name="Grid Voltage Phase 3",
|
||||
),
|
||||
"grid_current_phase1": CurrentFieldAttributes(
|
||||
name="Grid Current Phase 1",
|
||||
),
|
||||
"grid_current_phase2": CurrentFieldAttributes(
|
||||
name="Grid Current Phase 2",
|
||||
),
|
||||
"grid_current_phase3": CurrentFieldAttributes(
|
||||
name="Grid Current Phase 3",
|
||||
),
|
||||
"ac_output_frequency": FrequencyFieldAttributes(
|
||||
name="AC Output Frequency",
|
||||
),
|
||||
"ac_output_power_phase1": PowerFieldAttributes(
|
||||
name="AC Output Power Phase 1",
|
||||
),
|
||||
"ac_output_power_phase2": PowerFieldAttributes(
|
||||
name="AC Output Power Phase 2",
|
||||
),
|
||||
"ac_output_power_phase3": PowerFieldAttributes(
|
||||
name="AC Output Power Phase 3",
|
||||
),
|
||||
"ac_output_voltage_phase1": VoltageFieldAttributes(
|
||||
name="AC Output Voltage Phase 1",
|
||||
),
|
||||
"ac_output_voltage_phase2": VoltageFieldAttributes(
|
||||
name="AC Output Voltage Phase 2",
|
||||
),
|
||||
"ac_output_voltage_phase3": VoltageFieldAttributes(
|
||||
name="AC Output Voltage Phase 3",
|
||||
),
|
||||
"total_ac_consumption": EnergyFieldAttributes(
|
||||
name="Total Load Consumption",
|
||||
),
|
||||
"total_grid_consumption": EnergyFieldAttributes(
|
||||
name="Total Grid Consumption",
|
||||
),
|
||||
"total_grid_feed": EnergyFieldAttributes(
|
||||
name="Total Grid Feed",
|
||||
),
|
||||
# Device specific controls
|
||||
"power_off": FieldAttributes(
|
||||
type=FieldType.BUTTON,
|
||||
|
||||
Reference in new issue
Block a user