Compare commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
5bd98d6de3 | ||
|
|
2a4c3e943c | ||
|
|
dcfebb0f84 | ||
|
|
44dbd2b965 | ||
|
|
89928e2d9c | ||
|
|
dc3aaf92e1 | ||
|
|
95b1dafeb1 | ||
|
|
15a890fb7d | ||
|
|
542f244a28 | ||
|
|
eb701de865 | ||
|
|
f8ed8141ac | ||
|
|
bf86fe172b | ||
|
|
babdd1755e | ||
|
|
7596f8cee1 | ||
|
|
98d2a0b73e | ||
|
|
c499fbcd9b | ||
|
|
ec996d5728 |
No files matched your search
@@ -19,6 +19,7 @@ After the installation, you can use this button to install the integration:
|
||||
- AC60
|
||||
- AC180 (basic data)
|
||||
- AC180P (basic data)
|
||||
- AC200L (untested)
|
||||
- AC200M
|
||||
- AC300 (tested)
|
||||
- AC500
|
||||
|
||||
@@ -33,6 +33,8 @@ _LOGGER = logging.getLogger(__name__)
|
||||
async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
|
||||
"""Set up Bluetti Powerstation from a config entry."""
|
||||
|
||||
_LOGGER.debug("Init Bluetti BT Integration")
|
||||
|
||||
address = entry.data.get(CONF_ADDRESS)
|
||||
device_name = entry.data.get(CONF_NAME)
|
||||
use_controls = entry.data.get(CONF_USE_CONTROLS)
|
||||
@@ -53,10 +55,12 @@ async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
|
||||
hass.data[DOMAIN][entry.entry_id].setdefault(DATA_POLLING_RUNNING, False)
|
||||
|
||||
# Create coordinator for polling
|
||||
_LOGGER.debug("Creating coordinator")
|
||||
coordinator = PollingCoordinator(hass, address, device_name, polling_interval, persistent_conn, polling_timeout, max_retries)
|
||||
await coordinator.async_config_entry_first_refresh()
|
||||
hass.data[DOMAIN][entry.entry_id].setdefault(DATA_COORDINATOR, coordinator)
|
||||
|
||||
_LOGGER.debug("Creating entities")
|
||||
platforms: list = PLATFORMS
|
||||
if use_controls is True:
|
||||
_LOGGER.warning("You are using controls with this integration at your own risk!")
|
||||
@@ -65,6 +69,8 @@ async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
|
||||
# Setup platforms
|
||||
await hass.config_entries.async_forward_entry_setups(entry, platforms)
|
||||
|
||||
_LOGGER.debug("Setup done")
|
||||
|
||||
return True
|
||||
|
||||
|
||||
|
||||
@@ -29,13 +29,6 @@ class ProtocolV1Device(BluettiDevice):
|
||||
# Battery
|
||||
self.struct.add_uint_field("total_battery_percent", 43)
|
||||
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
|
||||
# Output state
|
||||
self.struct.add_bool_field("ac_output_on", 48)
|
||||
self.struct.add_bool_field("dc_output_on", 49)
|
||||
@@ -56,20 +49,10 @@ class ProtocolV1Device(BluettiDevice):
|
||||
ReadHoldingRegisters(36, 4),
|
||||
ReadHoldingRegisters(41, 1),
|
||||
ReadHoldingRegisters(43, 1),
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(48, 2),
|
||||
ReadHoldingRegisters(3007, 2),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return [range(3006, 3008)]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
]
|
||||
return [range(3006, 3009)]
|
||||
@@ -0,0 +1,59 @@
|
||||
"""AC200L fields."""
|
||||
|
||||
from typing import List
|
||||
|
||||
from ..utils.commands import ReadHoldingRegisters
|
||||
from ..field_enums import AutoSleepMode, OutputMode
|
||||
from ..base_devices.ProtocolV1Device import ProtocolV1Device
|
||||
|
||||
|
||||
class AC200L(ProtocolV1Device):
|
||||
def __init__(self, address: str, sn: str):
|
||||
super().__init__(address, "AC200L", sn)
|
||||
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_uint_field("internal_dc_input_voltage", 86)
|
||||
self.struct.add_decimal_field("internal_dc_input_power", 87, 1)
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
|
||||
# Controls
|
||||
self.struct.add_bool_field("power_off", 3060)
|
||||
self.struct.add_enum_field("auto_sleep_mode", 3061, AutoSleepMode)
|
||||
|
||||
@property
|
||||
def pack_num_max(self):
|
||||
return 3
|
||||
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 5),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3060, 2),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [range(3060, 3062)]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16)
|
||||
]
|
||||
@@ -13,15 +13,20 @@ class AC200M(ProtocolV1Device):
|
||||
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_uint_field("internal_ac_voltage", 71)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 1)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_uint_field("internal_dc_input_voltage", 86)
|
||||
self.struct.add_decimal_field("internal_dc_input_power", 87, 1)
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
|
||||
# Controls
|
||||
@@ -35,14 +40,20 @@ class AC200M(ProtocolV1Device):
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 4),
|
||||
ReadHoldingRegisters(70, 5),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3060, 2),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [range(3060, 3061)]
|
||||
return super().writable_ranges + [range(3060, 3062)]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().pack_polling_commands + [ReadHoldingRegisters(105, 16)]
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16)
|
||||
]
|
||||
@@ -11,12 +11,12 @@ class AC300(ProtocolV1Device):
|
||||
def __init__(self, address: str, sn: str):
|
||||
super().__init__(address, "AC300", sn)
|
||||
|
||||
# Details (matches EP500 + AC500)
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_uint_field("internal_ac_voltage", 71)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 1)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_decimal_field("internal_current_two", 75, 1)
|
||||
self.struct.add_uint_field("internal_power_two", 76)
|
||||
self.struct.add_decimal_field("ac_input_voltage", 77, 1)
|
||||
@@ -28,10 +28,15 @@ class AC300(ProtocolV1Device):
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
self.struct.add_version_field("pack_bms_version", 201)
|
||||
|
||||
# Controls (matches EP500 + AC500)
|
||||
# Controls
|
||||
self.struct.add_enum_field("ups_mode", 3001, UpsMode)
|
||||
self.struct.add_bool_field("split_phase_on", 3004)
|
||||
self.struct.add_enum_field(
|
||||
@@ -50,20 +55,29 @@ class AC300(ProtocolV1Device):
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 10),
|
||||
ReadHoldingRegisters(70, 11),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3001, 1),
|
||||
ReadHoldingRegisters(3004, 2),
|
||||
ReadHoldingRegisters(3011, 1),
|
||||
ReadHoldingRegisters(3013, 1),
|
||||
ReadHoldingRegisters(3015, 2),
|
||||
ReadHoldingRegisters(3061, 1),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3016),
|
||||
3061,
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().pack_polling_commands + [
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16),
|
||||
ReadHoldingRegisters(201, 2),
|
||||
]
|
||||
@@ -11,12 +11,12 @@ class AC500(ProtocolV1Device):
|
||||
def __init__(self, address: str, sn: str):
|
||||
super().__init__(address, "AC500", sn)
|
||||
|
||||
# Details (matches EP500 + AC300)
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_uint_field("internal_ac_voltage", 71)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 1)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_decimal_field("internal_current_two", 75, 1)
|
||||
self.struct.add_uint_field("internal_power_two", 76)
|
||||
self.struct.add_decimal_field("ac_input_voltage", 77, 1)
|
||||
@@ -27,10 +27,15 @@ class AC500(ProtocolV1Device):
|
||||
self.struct.add_decimal_field("internal_dc_input_power", 87, 1)
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs (matches EP500)
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
|
||||
# Controls (matches EP500 + AC300)
|
||||
# Controls
|
||||
self.struct.add_enum_field("ups_mode", 3001, UpsMode)
|
||||
self.struct.add_bool_field("split_phase_on", 3004)
|
||||
self.struct.add_enum_field(
|
||||
@@ -49,19 +54,28 @@ class AC500(ProtocolV1Device):
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 10),
|
||||
ReadHoldingRegisters(70, 11),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3001, 1),
|
||||
ReadHoldingRegisters(3004, 2),
|
||||
ReadHoldingRegisters(3011, 1),
|
||||
ReadHoldingRegisters(3013, 1),
|
||||
ReadHoldingRegisters(3015, 2),
|
||||
ReadHoldingRegisters(3061, 1),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3016),
|
||||
3061,
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().pack_polling_commands + [
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16),
|
||||
]
|
||||
@@ -28,12 +28,15 @@ class EB3A(ProtocolV1Device):
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(77, 1),
|
||||
ReadHoldingRegisters(86, 1),
|
||||
ReadHoldingRegisters(3034, 1),
|
||||
ReadHoldingRegisters(3060, 1),
|
||||
ReadHoldingRegisters(3063, 5),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
3034,
|
||||
3060,
|
||||
range(3063, 3066),
|
||||
range(3034, 3035),
|
||||
range(3060, 3061),
|
||||
range(3063, 3067),
|
||||
]
|
||||
@@ -11,12 +11,12 @@ class EP500(ProtocolV1Device):
|
||||
def __init__(self, address: str, sn: str):
|
||||
super().__init__(address, "EP500", sn)
|
||||
|
||||
# Details (matches AC500 + AC300)
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_uint_field("internal_ac_voltage", 71)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 1)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_decimal_field("internal_current_two", 75, 1)
|
||||
self.struct.add_uint_field("internal_power_two", 76)
|
||||
self.struct.add_decimal_field("ac_input_voltage", 77, 1)
|
||||
@@ -27,10 +27,15 @@ class EP500(ProtocolV1Device):
|
||||
self.struct.add_decimal_field("internal_dc_input_power", 87, 1)
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs (matches AC500)
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
|
||||
# Controls (matches AC500 + AC300)
|
||||
# Controls
|
||||
self.struct.add_enum_field("ups_mode", 3001, UpsMode)
|
||||
self.struct.add_bool_field("split_phase_on", 3004)
|
||||
self.struct.add_enum_field(
|
||||
@@ -45,19 +50,28 @@ class EP500(ProtocolV1Device):
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 10),
|
||||
ReadHoldingRegisters(70, 11),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3001, 1),
|
||||
ReadHoldingRegisters(3004, 2),
|
||||
ReadHoldingRegisters(3011, 1),
|
||||
ReadHoldingRegisters(3013, 1),
|
||||
ReadHoldingRegisters(3015, 2),
|
||||
ReadHoldingRegisters(3061, 1),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3016),
|
||||
3061,
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().pack_polling_commands + [
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16),
|
||||
]
|
||||
@@ -11,12 +11,12 @@ class EP500P(ProtocolV1Device):
|
||||
def __init__(self, address: str, sn: str):
|
||||
super().__init__(address, "EP500P", sn)
|
||||
|
||||
# Details (matches AC500 + AC300)
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_uint_field("internal_ac_voltage", 71)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 1)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_decimal_field("internal_current_two", 75, 1)
|
||||
self.struct.add_uint_field("internal_power_two", 76)
|
||||
self.struct.add_decimal_field("ac_input_voltage", 77, 1)
|
||||
@@ -27,10 +27,15 @@ class EP500P(ProtocolV1Device):
|
||||
self.struct.add_decimal_field("internal_dc_input_power", 87, 1)
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs (matches AC500)
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
|
||||
# Controls (matches AC500 + AC300)
|
||||
# Controls
|
||||
self.struct.add_enum_field("ups_mode", 3001, UpsMode)
|
||||
self.struct.add_bool_field("split_phase_on", 3004)
|
||||
self.struct.add_enum_field(
|
||||
@@ -45,19 +50,28 @@ class EP500P(ProtocolV1Device):
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 10),
|
||||
ReadHoldingRegisters(70, 11),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3001, 1),
|
||||
ReadHoldingRegisters(3004, 2),
|
||||
ReadHoldingRegisters(3011, 1),
|
||||
ReadHoldingRegisters(3013, 1),
|
||||
ReadHoldingRegisters(3015, 2),
|
||||
ReadHoldingRegisters(3061, 1),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3016),
|
||||
3061,
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().pack_polling_commands + [
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16),
|
||||
]
|
||||
@@ -79,10 +79,6 @@ class EP600(ProtocolV2Device):
|
||||
self.struct.add_version_field("safety_module_version", 6181) # internal
|
||||
self.struct.add_version_field("high_voltage_module_version", 6184) # internal
|
||||
|
||||
# @property
|
||||
# def pack_num_max(self):
|
||||
# return 16
|
||||
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
@@ -105,10 +101,3 @@ class EP600(ProtocolV2Device):
|
||||
ReadHoldingRegisters(156, 1),
|
||||
ReadHoldingRegisters(158, 1),
|
||||
]
|
||||
|
||||
# @property
|
||||
# def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
# return super().pack_polling_commands + [
|
||||
# ReadHoldingRegisters(6101, 10),
|
||||
# ReadHoldingRegisters(6175, 12),
|
||||
# ]
|
||||
@@ -18,7 +18,6 @@ class FieldType(Enum):
|
||||
NUMERIC = auto()
|
||||
BOOL = auto()
|
||||
ENUM = auto()
|
||||
BUTTON = auto()
|
||||
|
||||
|
||||
class FieldAttributes:
|
||||
@@ -220,7 +219,7 @@ FIELD_ATTRIBUTES: dict[str, FieldAttributes] = {
|
||||
"total_grid_feed": EnergyFieldAttributes("Total Grid Feed"),
|
||||
# Device specific controls
|
||||
"power_off": FieldAttributes(
|
||||
type=FieldType.BUTTON,
|
||||
type=FieldType.BOOL,
|
||||
setter=True,
|
||||
name="Power Off",
|
||||
),
|
||||
@@ -294,7 +293,7 @@ FIELD_ATTRIBUTES: dict[str, FieldAttributes] = {
|
||||
),
|
||||
"power_lifting_on": FieldAttributes(
|
||||
type=FieldType.BOOL,
|
||||
setter=False, # Disabled for safety reasons
|
||||
setter=True,
|
||||
name="Power Lifting",
|
||||
),
|
||||
}
|
||||
|
||||
@@ -5,6 +5,7 @@ import re
|
||||
from ..devices.ac60 import AC60
|
||||
from ..devices.ac180 import AC180
|
||||
from ..devices.ac180p import AC180P
|
||||
from ..devices.ac200l import AC200L
|
||||
from ..devices.ac200m import AC200M
|
||||
from ..devices.ac300 import AC300
|
||||
from ..devices.ac500 import AC500
|
||||
@@ -16,7 +17,7 @@ from ..devices.ep760 import EP760
|
||||
from ..devices.ep800 import EP800
|
||||
|
||||
DEVICE_NAME_RE = re.compile(
|
||||
r"^(AC60|AC180|AC180P|AC200M|AC300|AC500|EB3A|EP500|EP500P|EP600|EP760|EP800)(\d+)$"
|
||||
r"^(AC60|AC180|AC180P|AC200L|AC200M|AC300|AC500|EB3A|EP500|EP500P|EP600|EP760|EP800)(\d+)$"
|
||||
)
|
||||
|
||||
|
||||
@@ -28,6 +29,8 @@ def build_device(address: str, name: str):
|
||||
return AC180(address, match[2])
|
||||
if match[1] == "AC180P":
|
||||
return AC180P(address, match[2])
|
||||
if match[1] == "AC200L":
|
||||
return AC200L(address, match[2])
|
||||
if match[1] == "AC200M":
|
||||
return AC200M(address, match[2])
|
||||
if match[1] == "AC300":
|
||||
|
||||
@@ -26,8 +26,11 @@ SUPPORTED_MODELS = [
|
||||
]
|
||||
|
||||
CONTROL_FIELDS = [
|
||||
"ac_output_on",
|
||||
"dc_output_on",
|
||||
"ac_output_on_switch",
|
||||
"dc_output_on_switch",
|
||||
"power_off",
|
||||
"eco_on",
|
||||
"power_lifting_on",
|
||||
]
|
||||
|
||||
DIAGNOSTIC_FIELDS = [
|
||||
|
||||
@@ -4,6 +4,7 @@
|
||||
"bluetooth": [
|
||||
{ "local_name": "AC60*" },
|
||||
{ "local_name": "AC180*" },
|
||||
{ "local_name": "AC200L*" },
|
||||
{ "local_name": "AC200M*" },
|
||||
{ "local_name": "AC300*" },
|
||||
{ "local_name": "AC500*" },
|
||||
@@ -16,11 +17,11 @@
|
||||
],
|
||||
"codeowners": ["@Patrick762"],
|
||||
"config_flow": true,
|
||||
"dependencies": ["bluetooth"],
|
||||
"dependencies": ["bluetooth_adapters"],
|
||||
"documentation": "https://github.com/Patrick762/hassio-bluetti-bt",
|
||||
"integration_type": "device",
|
||||
"iot_class": "local_polling",
|
||||
"issue_tracker": "https://github.com/Patrick762/hassio-bluetti-bt/issues",
|
||||
"requirements": [],
|
||||
"version": "0.0.19"
|
||||
"version": "0.0.22"
|
||||
}
|
||||
@@ -175,10 +175,9 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
|
||||
if (
|
||||
self._options is not None
|
||||
and isinstance(response_data, Enum)
|
||||
and response_data.value < len(self._options)
|
||||
):
|
||||
# Enum
|
||||
self._attr_native_value = self._options[response_data.value]
|
||||
self._attr_native_value = response_data.name
|
||||
else:
|
||||
# Numeric
|
||||
self._attr_native_value = response_data
|
||||
|
||||
Reference in new issue
Block a user