Compare commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
dc3aaf92e1 | ||
|
|
95b1dafeb1 | ||
|
|
15a890fb7d | ||
|
|
542f244a28 | ||
|
|
eb701de865 | ||
|
|
f8ed8141ac | ||
|
|
bf86fe172b | ||
|
|
babdd1755e | ||
|
|
7596f8cee1 | ||
|
|
98d2a0b73e | ||
|
|
c499fbcd9b | ||
|
|
ec996d5728 |
No files matched your search
@@ -33,6 +33,8 @@ _LOGGER = logging.getLogger(__name__)
|
||||
async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
|
||||
"""Set up Bluetti Powerstation from a config entry."""
|
||||
|
||||
_LOGGER.debug("Init Bluetti BT Integration")
|
||||
|
||||
address = entry.data.get(CONF_ADDRESS)
|
||||
device_name = entry.data.get(CONF_NAME)
|
||||
use_controls = entry.data.get(CONF_USE_CONTROLS)
|
||||
@@ -53,10 +55,12 @@ async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
|
||||
hass.data[DOMAIN][entry.entry_id].setdefault(DATA_POLLING_RUNNING, False)
|
||||
|
||||
# Create coordinator for polling
|
||||
_LOGGER.debug("Creating coordinator")
|
||||
coordinator = PollingCoordinator(hass, address, device_name, polling_interval, persistent_conn, polling_timeout, max_retries)
|
||||
await coordinator.async_config_entry_first_refresh()
|
||||
hass.data[DOMAIN][entry.entry_id].setdefault(DATA_COORDINATOR, coordinator)
|
||||
|
||||
_LOGGER.debug("Creating entities")
|
||||
platforms: list = PLATFORMS
|
||||
if use_controls is True:
|
||||
_LOGGER.warning("You are using controls with this integration at your own risk!")
|
||||
@@ -65,6 +69,8 @@ async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
|
||||
# Setup platforms
|
||||
await hass.config_entries.async_forward_entry_setups(entry, platforms)
|
||||
|
||||
_LOGGER.debug("Setup done")
|
||||
|
||||
return True
|
||||
|
||||
|
||||
|
||||
@@ -29,13 +29,6 @@ class ProtocolV1Device(BluettiDevice):
|
||||
# Battery
|
||||
self.struct.add_uint_field("total_battery_percent", 43)
|
||||
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
|
||||
# Output state
|
||||
self.struct.add_bool_field("ac_output_on", 48)
|
||||
self.struct.add_bool_field("dc_output_on", 49)
|
||||
@@ -56,20 +49,10 @@ class ProtocolV1Device(BluettiDevice):
|
||||
ReadHoldingRegisters(36, 4),
|
||||
ReadHoldingRegisters(41, 1),
|
||||
ReadHoldingRegisters(43, 1),
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(48, 2),
|
||||
ReadHoldingRegisters(3007, 2),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return [range(3006, 3008)]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
]
|
||||
return [range(3006, 3009)]
|
||||
@@ -13,15 +13,20 @@ class AC200M(ProtocolV1Device):
|
||||
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_uint_field("internal_ac_voltage", 71)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 1)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_uint_field("internal_dc_input_voltage", 86)
|
||||
self.struct.add_decimal_field("internal_dc_input_power", 87, 1)
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
|
||||
# Controls
|
||||
@@ -35,14 +40,20 @@ class AC200M(ProtocolV1Device):
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 4),
|
||||
ReadHoldingRegisters(70, 5),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3060, 2),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [range(3060, 3061)]
|
||||
return super().writable_ranges + [range(3060, 3062)]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().pack_polling_commands + [ReadHoldingRegisters(105, 16)]
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16)
|
||||
]
|
||||
@@ -11,12 +11,12 @@ class AC300(ProtocolV1Device):
|
||||
def __init__(self, address: str, sn: str):
|
||||
super().__init__(address, "AC300", sn)
|
||||
|
||||
# Details (matches EP500 + AC500)
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_uint_field("internal_ac_voltage", 71)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 1)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_decimal_field("internal_current_two", 75, 1)
|
||||
self.struct.add_uint_field("internal_power_two", 76)
|
||||
self.struct.add_decimal_field("ac_input_voltage", 77, 1)
|
||||
@@ -28,10 +28,15 @@ class AC300(ProtocolV1Device):
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
self.struct.add_version_field("pack_bms_version", 201)
|
||||
|
||||
# Controls (matches EP500 + AC500)
|
||||
# Controls
|
||||
self.struct.add_enum_field("ups_mode", 3001, UpsMode)
|
||||
self.struct.add_bool_field("split_phase_on", 3004)
|
||||
self.struct.add_enum_field(
|
||||
@@ -50,20 +55,29 @@ class AC300(ProtocolV1Device):
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 10),
|
||||
ReadHoldingRegisters(70, 11),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3001, 1),
|
||||
ReadHoldingRegisters(3004, 2),
|
||||
ReadHoldingRegisters(3011, 1),
|
||||
ReadHoldingRegisters(3013, 1),
|
||||
ReadHoldingRegisters(3015, 2),
|
||||
ReadHoldingRegisters(3061, 1),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3016),
|
||||
3061,
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().pack_polling_commands + [
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16),
|
||||
ReadHoldingRegisters(201, 2),
|
||||
]
|
||||
@@ -11,12 +11,12 @@ class AC500(ProtocolV1Device):
|
||||
def __init__(self, address: str, sn: str):
|
||||
super().__init__(address, "AC500", sn)
|
||||
|
||||
# Details (matches EP500 + AC300)
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_uint_field("internal_ac_voltage", 71)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 1)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_decimal_field("internal_current_two", 75, 1)
|
||||
self.struct.add_uint_field("internal_power_two", 76)
|
||||
self.struct.add_decimal_field("ac_input_voltage", 77, 1)
|
||||
@@ -27,10 +27,15 @@ class AC500(ProtocolV1Device):
|
||||
self.struct.add_decimal_field("internal_dc_input_power", 87, 1)
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs (matches EP500)
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
|
||||
# Controls (matches EP500 + AC300)
|
||||
# Controls
|
||||
self.struct.add_enum_field("ups_mode", 3001, UpsMode)
|
||||
self.struct.add_bool_field("split_phase_on", 3004)
|
||||
self.struct.add_enum_field(
|
||||
@@ -49,19 +54,28 @@ class AC500(ProtocolV1Device):
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 10),
|
||||
ReadHoldingRegisters(70, 11),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3001, 1),
|
||||
ReadHoldingRegisters(3004, 2),
|
||||
ReadHoldingRegisters(3011, 1),
|
||||
ReadHoldingRegisters(3013, 1),
|
||||
ReadHoldingRegisters(3015, 2),
|
||||
ReadHoldingRegisters(3061, 1),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3016),
|
||||
3061,
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().pack_polling_commands + [
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16),
|
||||
]
|
||||
@@ -28,12 +28,15 @@ class EB3A(ProtocolV1Device):
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(77, 1),
|
||||
ReadHoldingRegisters(86, 1),
|
||||
ReadHoldingRegisters(3034, 1),
|
||||
ReadHoldingRegisters(3060, 1),
|
||||
ReadHoldingRegisters(3063, 5),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
3034,
|
||||
3060,
|
||||
range(3063, 3066),
|
||||
range(3034, 3035),
|
||||
range(3060, 3061),
|
||||
range(3063, 3067),
|
||||
]
|
||||
@@ -11,12 +11,12 @@ class EP500(ProtocolV1Device):
|
||||
def __init__(self, address: str, sn: str):
|
||||
super().__init__(address, "EP500", sn)
|
||||
|
||||
# Details (matches AC500 + AC300)
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_uint_field("internal_ac_voltage", 71)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 1)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_decimal_field("internal_current_two", 75, 1)
|
||||
self.struct.add_uint_field("internal_power_two", 76)
|
||||
self.struct.add_decimal_field("ac_input_voltage", 77, 1)
|
||||
@@ -27,10 +27,15 @@ class EP500(ProtocolV1Device):
|
||||
self.struct.add_decimal_field("internal_dc_input_power", 87, 1)
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs (matches AC500)
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
|
||||
# Controls (matches AC500 + AC300)
|
||||
# Controls
|
||||
self.struct.add_enum_field("ups_mode", 3001, UpsMode)
|
||||
self.struct.add_bool_field("split_phase_on", 3004)
|
||||
self.struct.add_enum_field(
|
||||
@@ -45,19 +50,28 @@ class EP500(ProtocolV1Device):
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 10),
|
||||
ReadHoldingRegisters(70, 11),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3001, 1),
|
||||
ReadHoldingRegisters(3004, 2),
|
||||
ReadHoldingRegisters(3011, 1),
|
||||
ReadHoldingRegisters(3013, 1),
|
||||
ReadHoldingRegisters(3015, 2),
|
||||
ReadHoldingRegisters(3061, 1),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3016),
|
||||
3061,
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().pack_polling_commands + [
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16),
|
||||
]
|
||||
@@ -11,12 +11,12 @@ class EP500P(ProtocolV1Device):
|
||||
def __init__(self, address: str, sn: str):
|
||||
super().__init__(address, "EP500P", sn)
|
||||
|
||||
# Details (matches AC500 + AC300)
|
||||
# Details
|
||||
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
|
||||
self.struct.add_uint_field("internal_ac_voltage", 71)
|
||||
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
|
||||
self.struct.add_decimal_field("internal_current_one", 72, 1)
|
||||
self.struct.add_uint_field("internal_power_one", 73)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 1)
|
||||
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
|
||||
self.struct.add_decimal_field("internal_current_two", 75, 1)
|
||||
self.struct.add_uint_field("internal_power_two", 76)
|
||||
self.struct.add_decimal_field("ac_input_voltage", 77, 1)
|
||||
@@ -27,10 +27,15 @@ class EP500P(ProtocolV1Device):
|
||||
self.struct.add_decimal_field("internal_dc_input_power", 87, 1)
|
||||
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
|
||||
|
||||
# Battery packs (matches AC500)
|
||||
# Battery packs
|
||||
self.struct.add_uint_field("pack_num_max", 91) # internal
|
||||
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
|
||||
self.struct.add_uint_field("pack_num", 96) # internal
|
||||
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
|
||||
self.struct.add_uint_field("pack_battery_percent", 99)
|
||||
self.struct.add_decimal_array_field("cell_voltages", 105, 16, 2) # internal
|
||||
|
||||
# Controls (matches AC500 + AC300)
|
||||
# Controls
|
||||
self.struct.add_enum_field("ups_mode", 3001, UpsMode)
|
||||
self.struct.add_bool_field("split_phase_on", 3004)
|
||||
self.struct.add_enum_field(
|
||||
@@ -45,19 +50,28 @@ class EP500P(ProtocolV1Device):
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
ReadHoldingRegisters(70, 10),
|
||||
ReadHoldingRegisters(70, 11),
|
||||
ReadHoldingRegisters(86, 3),
|
||||
ReadHoldingRegisters(3001, 1),
|
||||
ReadHoldingRegisters(3004, 2),
|
||||
ReadHoldingRegisters(3011, 1),
|
||||
ReadHoldingRegisters(3013, 1),
|
||||
ReadHoldingRegisters(3015, 2),
|
||||
ReadHoldingRegisters(3061, 1),
|
||||
]
|
||||
|
||||
@property
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3016),
|
||||
3061,
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
]
|
||||
|
||||
@property
|
||||
def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().pack_polling_commands + [
|
||||
return [
|
||||
ReadHoldingRegisters(91, 2),
|
||||
ReadHoldingRegisters(96, 1),
|
||||
ReadHoldingRegisters(98, 2),
|
||||
ReadHoldingRegisters(105, 16),
|
||||
]
|
||||
@@ -79,10 +79,6 @@ class EP600(ProtocolV2Device):
|
||||
self.struct.add_version_field("safety_module_version", 6181) # internal
|
||||
self.struct.add_version_field("high_voltage_module_version", 6184) # internal
|
||||
|
||||
# @property
|
||||
# def pack_num_max(self):
|
||||
# return 16
|
||||
|
||||
@property
|
||||
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
return super().polling_commands + [
|
||||
@@ -105,10 +101,3 @@ class EP600(ProtocolV2Device):
|
||||
ReadHoldingRegisters(156, 1),
|
||||
ReadHoldingRegisters(158, 1),
|
||||
]
|
||||
|
||||
# @property
|
||||
# def pack_polling_commands(self) -> List[ReadHoldingRegisters]:
|
||||
# return super().pack_polling_commands + [
|
||||
# ReadHoldingRegisters(6101, 10),
|
||||
# ReadHoldingRegisters(6175, 12),
|
||||
# ]
|
||||
@@ -18,7 +18,6 @@ class FieldType(Enum):
|
||||
NUMERIC = auto()
|
||||
BOOL = auto()
|
||||
ENUM = auto()
|
||||
BUTTON = auto()
|
||||
|
||||
|
||||
class FieldAttributes:
|
||||
@@ -220,7 +219,7 @@ FIELD_ATTRIBUTES: dict[str, FieldAttributes] = {
|
||||
"total_grid_feed": EnergyFieldAttributes("Total Grid Feed"),
|
||||
# Device specific controls
|
||||
"power_off": FieldAttributes(
|
||||
type=FieldType.BUTTON,
|
||||
type=FieldType.BOOL,
|
||||
setter=True,
|
||||
name="Power Off",
|
||||
),
|
||||
@@ -294,7 +293,7 @@ FIELD_ATTRIBUTES: dict[str, FieldAttributes] = {
|
||||
),
|
||||
"power_lifting_on": FieldAttributes(
|
||||
type=FieldType.BOOL,
|
||||
setter=False, # Disabled for safety reasons
|
||||
setter=True,
|
||||
name="Power Lifting",
|
||||
),
|
||||
}
|
||||
|
||||
@@ -26,8 +26,11 @@ SUPPORTED_MODELS = [
|
||||
]
|
||||
|
||||
CONTROL_FIELDS = [
|
||||
"ac_output_on",
|
||||
"dc_output_on",
|
||||
"ac_output_on_switch",
|
||||
"dc_output_on_switch",
|
||||
"power_off",
|
||||
"eco_on",
|
||||
"power_lifting_on",
|
||||
]
|
||||
|
||||
DIAGNOSTIC_FIELDS = [
|
||||
|
||||
@@ -22,5 +22,5 @@
|
||||
"iot_class": "local_polling",
|
||||
"issue_tracker": "https://github.com/Patrick762/hassio-bluetti-bt/issues",
|
||||
"requirements": [],
|
||||
"version": "0.0.19"
|
||||
"version": "0.0.21"
|
||||
}
|
||||
@@ -175,10 +175,9 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
|
||||
if (
|
||||
self._options is not None
|
||||
and isinstance(response_data, Enum)
|
||||
and response_data.value < len(self._options)
|
||||
):
|
||||
# Enum
|
||||
self._attr_native_value = self._options[response_data.value]
|
||||
self._attr_native_value = response_data.name
|
||||
else:
|
||||
# Numeric
|
||||
self._attr_native_value = response_data
|
||||
|
||||
Reference in new issue
Block a user