Compare commits

...
13 Commits
4 changed files with 207 additions and 23 deletions

No files matched your search

@@ -4,7 +4,6 @@ from __future__ import annotations
import logging
from homeassistant.components import bluetooth
from homeassistant.components.binary_sensor import BinarySensorEntity
from homeassistant.config_entries import ConfigEntry
from homeassistant.core import HomeAssistant, callback
@@ -28,7 +27,7 @@ from bluetti_mqtt.mqtt_client import (
from . import device_info as dev_info, get_unique_id
from .const import DOMAIN, ADDITIONAL_DEVICE_FIELDS
from .coordinator import PollingCoordinator
from .coordinator import PollingCoordinator, DummyDevice
_LOGGER = logging.getLogger(__name__)
@@ -49,6 +48,7 @@ async def async_setup_entry(
# Add sensors according to device_info
bluetti_device = build_device(address, device_name)
bluetti_device = DummyDevice(bluetti_device)
sensors_to_add = []
all_fields = NORMAL_DEVICE_FIELDS
@@ -96,15 +96,10 @@ class BluettiBinarySensor(CoordinatorEntity, BinarySensorEntity):
self._attr_device_info = device_info
self._attr_name = e_name
self._attr_available = False
self._attr_unique_id = get_unique_id(e_name)
self._attr_entity_category = category
@property
def available(self) -> bool:
if self._address is None:
return False
return bluetooth.async_address_present(self.hass, self._address)
@callback
def _handle_coordinator_update(self) -> None:
"""Handle updated data from the coordinator."""
@@ -113,10 +108,12 @@ class BluettiBinarySensor(CoordinatorEntity, BinarySensorEntity):
_LOGGER.error(
"Invalid data from coordinator (sensor.%s)", self._attr_unique_id
)
self._attr_available = False
return
response_data = self.coordinator.data.get(self._response_key)
if response_data is None:
self._attr_available = False
return
if not isinstance(response_data, bool):
@@ -125,7 +122,9 @@ class BluettiBinarySensor(CoordinatorEntity, BinarySensorEntity):
self._attr_unique_id,
response_data,
)
self._attr_available = False
return
self._attr_available = True
self._attr_is_on = self.coordinator.data[self._response_key] is True
self.async_write_ha_state()
+163
View File
@@ -8,11 +8,48 @@ MANUFACTURER = "Bluetti"
CONF_OPTIONS = "options"
DIAGNOSTIC_FIELDS = [
"max_ac_input_power",
"max_ac_input_current",
"max_ac_output_power",
"max_ac_output_current",
"bcu_version",
"safety_module_version",
"high_voltage_module_version",
]
ADDITIONAL_DEVICE_FIELDS = {
"max_ac_input_power": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Max AC Input Power per Phase",
},
),
"max_ac_input_current": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Max AC Input Current per Phase",
},
),
"max_ac_output_power": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Max AC Output Power per Phase",
},
),
"max_ac_output_current": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Max AC Output Current per Phase",
},
),
"bcu_version": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
@@ -25,4 +62,130 @@ ADDITIONAL_DEVICE_FIELDS = {
advanced=False,
home_assistant_extra={"name": "Safety Module Version"},
),
"high_voltage_module_version": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={"name": "High Voltage Safety Module Version"},
),
"adl400_ac_input_voltage_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "ADL400 AC Input Voltage Phase 1",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"adl400_ac_input_voltage_phase2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "ADL400 AC Input Voltage Phase 2",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"adl400_ac_input_voltage_phase3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "ADL400 AC Input Voltage Phase 3",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"ac_input_voltage_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Input Voltage Phase 1",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"ac_input_voltage_phase2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Input Voltage Phase 2",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"ac_input_voltage_phase3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Input Voltage Phase 3",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_voltage_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Voltage Phase 1",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_voltage_phase2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Voltage Phase 2",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_voltage_phase3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Voltage Phase 3",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_frequency": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Frequency",
"unit_of_measurement": "Hz",
"device_class": "frequency",
"state_class": "measurement",
"force_update": True,
},
),
}
+28 -6
View File
@@ -40,6 +40,20 @@ class DummyDevice(BluettiDevice):
def __init__(self, device: BluettiDevice):
"""Init dummy device with real device."""
self.struct = device.struct
if device.type == "EP600":
self.struct.add_decimal_field("adl400_ac_input_voltage_phase1", 1229, 1)
self.struct.add_decimal_field("adl400_ac_input_voltage_phase2", 1237, 1)
self.struct.add_decimal_field("adl400_ac_input_voltage_phase3", 1245, 1)
self.struct.add_decimal_field("ac_input_frequency", 1300, 1)
self.struct.add_decimal_field("ac_input_voltage_phase1", 1314, 1)
self.struct.add_decimal_field("ac_input_voltage_phase2", 1320, 1)
self.struct.add_decimal_field("ac_input_voltage_phase3", 1326, 1)
self.struct.add_decimal_field("ac_output_frequency", 1500, 1)
self.struct.add_decimal_field("ac_output_voltage_phase1", 1511, 1)
self.struct.add_decimal_field("ac_output_voltage_phase2", 1518, 1)
self.struct.add_decimal_field("ac_output_voltage_phase3", 1525, 1)
super().__init__(device.address, device.type, device.sn)
self._parent = device
@@ -48,10 +62,16 @@ class DummyDevice(BluettiDevice):
if self.type == "EP600":
return [
ReadHoldingRegisters(100, 62),
ReadHoldingRegisters(1229, 19),
ReadHoldingRegisters(1300, 1),
ReadHoldingRegisters(1314, 13),
ReadHoldingRegisters(1500, 1),
ReadHoldingRegisters(1511, 15),
ReadHoldingRegisters(2022, 6),
ReadHoldingRegisters(2213, 4),
# Battery
ReadHoldingRegisters(6101, 7),
ReadHoldingRegisters(6175, 2),
ReadHoldingRegisters(6181, 2),
ReadHoldingRegisters(6175, 11),
]
return self._parent.polling_commands
@@ -148,7 +168,7 @@ class PollingCoordinator(DataUpdateCoordinator):
command.starting_address, body
)
self.logger.error("Parsed data: %s", parsed)
self.logger.debug("Parsed data: %s", parsed)
parsed_data.update(parsed)
except TimeoutError:
@@ -156,15 +176,17 @@ class PollingCoordinator(DataUpdateCoordinator):
"Polling timed out (address: %s)", self._address
)
except ParseError:
self.logger.debug("Got a parse exception...")
self.logger.warning("Got a parse exception...")
except ModbusError as err:
self.logger.debug(
self.logger.warning(
"Got an invalid request error for %s: %s",
command,
err,
)
except (BadConnectionError, BleakError) as err:
self.logger.debug("Needed to disconnect due to error: %s", err)
self.logger.warning(
"Needed to disconnect due to error: %s", err
)
except TimeoutError:
self.logger.error("Polling timed out for device %s", self._address)
return None
+9 -9
View File
@@ -3,9 +3,8 @@
from __future__ import annotations
import logging
from decimal import *
from decimal import Decimal
from homeassistant.components import bluetooth
from homeassistant.components.sensor import SensorEntity, CONF_STATE_CLASS
from homeassistant.config_entries import ConfigEntry
from homeassistant.core import HomeAssistant, callback
@@ -31,7 +30,7 @@ from bluetti_mqtt.mqtt_client import (
from . import device_info as dev_info, get_unique_id
from .const import DOMAIN, CONF_OPTIONS, DIAGNOSTIC_FIELDS, ADDITIONAL_DEVICE_FIELDS
from .coordinator import PollingCoordinator
from .coordinator import PollingCoordinator, DummyDevice
_LOGGER = logging.getLogger(__name__)
@@ -52,6 +51,7 @@ async def async_setup_entry(
# Add sensors according to device_info
bluetti_device = build_device(address, device_name)
bluetti_device = DummyDevice(bluetti_device)
sensors_to_add = []
all_fields = NORMAL_DEVICE_FIELDS
@@ -117,6 +117,7 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
self._attr_device_info = device_info
self._attr_name = e_name
self._attr_available = False
self._attr_unique_id = get_unique_id(e_name)
self._attr_native_unit_of_measurement = unit_of_measurement
self._attr_device_class = device_class
@@ -124,12 +125,6 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
self._attr_entity_category = category
self._options = options
@property
def available(self) -> bool:
if self._address is None:
return False
return bluetooth.async_address_present(self.hass, self._address)
@callback
def _handle_coordinator_update(self) -> None:
"""Handle updated data from the coordinator."""
@@ -138,10 +133,12 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
_LOGGER.error(
"Invalid data from coordinator (sensor.%s)", self._attr_unique_id
)
self._attr_available = False
return
response_data = self.coordinator.data.get(self._response_key)
if response_data is None:
self._attr_available = False
return
if (
@@ -156,8 +153,11 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
response_data,
type(response_data),
)
self._attr_available = False
return
self._attr_available = True
# Different for enum and numeric
if (
self._options is not None