Compare commits

..
7 Commits
Author SHA1 Message Date
Patrick762 d54bf7c526 Merge pull request #7 from Patrick762/dev
Added more EP600 fields
2023-08-04 19:49:33 +02:00
Patrick762 22c2f0c7d0 edited comment 2023-08-04 19:49:22 +02:00
Patrick762 23dc2b7f41 renamed some fields, added grid input power fields 2023-08-04 19:47:42 +02:00
Patrick762 84a742968a added more ep600 fields 2023-08-04 19:27:58 +02:00
Patrick762 ed818070c2 Merge pull request #6 from Patrick762/dev
Updated EP600 fields
2023-08-03 22:01:00 +02:00
Patrick762 beb4e6b8fb added input and output frequency for ep600 2023-08-03 21:58:59 +02:00
Patrick762 7444097c60 added more ep600 voltage entities 2023-08-03 21:44:51 +02:00
2 changed files with 389 additions and 2 deletions

No files matched your search

+344
View File
@@ -68,6 +68,42 @@ ADDITIONAL_DEVICE_FIELDS = {
advanced=False, advanced=False,
home_assistant_extra={"name": "High Voltage Safety Module Version"}, home_assistant_extra={"name": "High Voltage Safety Module Version"},
), ),
"adl400_ac_input_power_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "ADL400 AC Input Power Phase 1",
"unit_of_measurement": "W",
"device_class": "power",
"state_class": "measurement",
"force_update": True,
},
),
"adl400_ac_input_power_phase2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "ADL400 AC Input Power Phase 2",
"unit_of_measurement": "W",
"device_class": "power",
"state_class": "measurement",
"force_update": True,
},
),
"adl400_ac_input_power_phase3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "ADL400 AC Input Power Phase 3",
"unit_of_measurement": "W",
"device_class": "power",
"state_class": "measurement",
"force_update": True,
},
),
"adl400_ac_input_voltage_phase1": MqttFieldConfig( "adl400_ac_input_voltage_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC, type=MqttFieldType.NUMERIC,
setter=False, setter=False,
@@ -104,4 +140,312 @@ ADDITIONAL_DEVICE_FIELDS = {
"force_update": True, "force_update": True,
}, },
), ),
"grid_input_voltage_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Grid Input Voltage Phase 1",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"grid_input_voltage_phase2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Grid Input Voltage Phase 2",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"grid_input_voltage_phase3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Grid Input Voltage Phase 3",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"grid_input_current_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Grid Input Current Phase 1",
"unit_of_measurement": "A",
"device_class": "current",
"state_class": "measurement",
"force_update": True,
},
),
"grid_input_current_phase2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Grid Input Current Phase 2",
"unit_of_measurement": "A",
"device_class": "current",
"state_class": "measurement",
"force_update": True,
},
),
"grid_input_current_phase3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Grid Input Current Phase 3",
"unit_of_measurement": "A",
"device_class": "current",
"state_class": "measurement",
"force_update": True,
},
),
"grid_input_power_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Grid Input Power Phase 1",
"unit_of_measurement": "W",
"device_class": "power",
"state_class": "measurement",
"force_update": True,
},
),
"grid_input_power_phase2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Grid Input Power Phase 2",
"unit_of_measurement": "W",
"device_class": "power",
"state_class": "measurement",
"force_update": True,
},
),
"grid_input_power_phase3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Grid Input Power Phase 3",
"unit_of_measurement": "W",
"device_class": "power",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_frequency": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Frequency",
"unit_of_measurement": "Hz",
"device_class": "frequency",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_voltage_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Voltage Phase 1",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_voltage_phase2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Voltage Phase 2",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_voltage_phase3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Voltage Phase 3",
"unit_of_measurement": "V",
"device_class": "voltage",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_power_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Power Phase 1",
"unit_of_measurement": "W",
"device_class": "power",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_power_phase2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Power Phase 2",
"unit_of_measurement": "W",
"device_class": "power",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_power_phase3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Power Phase 3",
"unit_of_measurement": "W",
"device_class": "power",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_current_phase1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Current Phase 1",
"unit_of_measurement": "A",
"device_class": "current",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_current_phase2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Current Phase 2",
"unit_of_measurement": "A",
"device_class": "current",
"state_class": "measurement",
"force_update": True,
},
),
"ac_output_current_phase3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "AC Output Current Phase 3",
"unit_of_measurement": "A",
"device_class": "current",
"state_class": "measurement",
"force_update": True,
},
),
"testing0": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Register Testing 0",
},
),
"testing1": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Register Testing 1",
},
),
"testing2": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Register Testing 2",
},
),
"testing3": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Register Testing 3",
},
),
"testing4": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Register Testing 4",
},
),
"testing5": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Register Testing 5",
},
),
"testing6": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Register Testing 6",
},
),
"testing7": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Register Testing 7",
},
),
"testing8": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Register Testing 8",
},
),
"testing9": MqttFieldConfig(
type=MqttFieldType.NUMERIC,
setter=False,
advanced=False,
home_assistant_extra={
"name": "Register Testing 9",
},
),
} }
+45 -2
View File
@@ -42,9 +42,38 @@ class DummyDevice(BluettiDevice):
self.struct = device.struct self.struct = device.struct
if device.type == "EP600": if device.type == "EP600":
# ADL400 Smart Meter for AC Solar
self.struct.add_uint_field("adl400_ac_input_power_phase1", 1228)
self.struct.add_uint_field("adl400_ac_input_power_phase2", 1236)
self.struct.add_uint_field("adl400_ac_input_power_phase3", 1244)
self.struct.add_decimal_field("adl400_ac_input_voltage_phase1", 1229, 1) self.struct.add_decimal_field("adl400_ac_input_voltage_phase1", 1229, 1)
self.struct.add_decimal_field("adl400_ac_input_voltage_phase2", 1237, 1) self.struct.add_decimal_field("adl400_ac_input_voltage_phase2", 1237, 1)
self.struct.add_decimal_field("adl400_ac_input_voltage_phase3", 1245, 1) self.struct.add_decimal_field("adl400_ac_input_voltage_phase3", 1245, 1)
# Grid Input
self.struct.add_decimal_field("grid_input_frequency", 1300, 1)
self.struct.add_uint_field("grid_input_power_phase1", 1313)
self.struct.add_uint_field("grid_input_power_phase2", 1319)
self.struct.add_uint_field("grid_input_power_phase3", 1325)
self.struct.add_decimal_field("grid_input_voltage_phase1", 1314, 1)
self.struct.add_decimal_field("grid_input_voltage_phase2", 1320, 1)
self.struct.add_decimal_field("grid_input_voltage_phase3", 1326, 1)
self.struct.add_decimal_field("grid_input_current_phase1", 1315, 1)
self.struct.add_decimal_field("grid_input_current_phase2", 1321, 1)
self.struct.add_decimal_field("grid_input_current_phase3", 1327, 1)
# EP600 AC Output
self.struct.add_decimal_field("ac_output_frequency", 1500, 1)
self.struct.add_uint_field("ac_output_power_phase1", 1510)
self.struct.add_uint_field("ac_output_power_phase2", 1517)
self.struct.add_uint_field("ac_output_power_phase3", 1524)
self.struct.add_decimal_field("ac_output_voltage_phase1", 1511, 1)
self.struct.add_decimal_field("ac_output_voltage_phase2", 1518, 1)
self.struct.add_decimal_field("ac_output_voltage_phase3", 1525, 1)
self.struct.add_decimal_field("ac_output_current_phase1", 1512, 1)
self.struct.add_decimal_field("ac_output_current_phase2", 1519, 1)
self.struct.add_decimal_field("ac_output_current_phase3", 1526, 1)
# Testing
# for i in range(0, 10):
# self.struct.add_decimal_field("testing"+str(i), 1520+i, 1)
super().__init__(device.address, device.type, device.sn) super().__init__(device.address, device.type, device.sn)
self._parent = device self._parent = device
@@ -54,13 +83,27 @@ class DummyDevice(BluettiDevice):
if self.type == "EP600": if self.type == "EP600":
return [ return [
ReadHoldingRegisters(100, 62), ReadHoldingRegisters(100, 62),
ReadHoldingRegisters(1229, 19), ReadHoldingRegisters(1228, 19),
ReadHoldingRegisters(1300, 28),
ReadHoldingRegisters(1500, 27),
ReadHoldingRegisters(2022, 6), ReadHoldingRegisters(2022, 6),
ReadHoldingRegisters(2213, 4), ReadHoldingRegisters(2213, 4),
# Battery # Battery
ReadHoldingRegisters(6101, 7), ReadHoldingRegisters(6101, 7),
ReadHoldingRegisters(6175, 11), ReadHoldingRegisters(6175, 11),
# current limit for reading ReadHoldingRegisters(0x2F2F, 1), # Testing
# ReadHoldingRegisters(100, 62),
# ReadHoldingRegisters(1100, 51),
# ReadHoldingRegisters(1200, 80),
# ReadHoldingRegisters(1300, 31),
# ReadHoldingRegisters(1400, 48),
# ReadHoldingRegisters(1500, 30),
# ReadHoldingRegisters(2000, 89),
# ReadHoldingRegisters(2200, 41),
# ReadHoldingRegisters(2300, 36),
# ReadHoldingRegisters(6000, 32),
# ReadHoldingRegisters(6100, 100),
# ReadHoldingRegisters(6300, 100),
] ]
return self._parent.polling_commands return self._parent.polling_commands