Compare commits

...
13 Commits
Author SHA1 Message Date
Patrick762 149633f9c8 Increase version number 2024-06-30 15:04:23 +02:00
Patrick762 9ab7cefda7 Merge pull request #116 from matthewpucc/main
Support AC70 and AC70P Device
2024-06-30 15:03:35 +02:00
Patrick762 52853d6d3e Merge pull request #117 from rotx/fix-multiply
Fix multiplication of Decimal with float
2024-06-30 15:03:14 +02:00
Robert Muchsel 3d3401c942 Fix multiplication of Decimal with float 2024-06-21 20:52:48 -05:00
Matthew Puccerella f50232ee89 Merge pull request #1 from matthewpucc/support_ac70_devices
Add support AC70 and AC70P devices
2024-06-20 16:12:53 -07:00
Matthew Puccerella 5922362772 Add support AC70 and AC70P devices 2024-06-20 23:11:47 +00:00
Patrick762 6478825503 Merge pull request #107 from Patrick762/next
Fixed values and improved unavailable handling
2024-06-02 14:06:20 +02:00
Patrick762 3169ee182e increase version number 2024-06-02 14:03:02 +02:00
Patrick762 ece1fc4129 only set unavailable after 5 retries 2024-06-02 13:58:21 +02:00
Patrick762 4d54e048c5 ignore packs not connected 2024-06-02 13:49:18 +02:00
Patrick762 09a9112279 check pack_num after setting it 2024-06-02 13:48:45 +02:00
Patrick762 b37276ec52 updated ac200l sensors based on feedback 2024-06-02 13:12:43 +02:00
Patrick762 4f88792371 Update bug_report.yaml 2024-05-31 17:16:26 +02:00
13 changed files with 124 additions and 38 deletions

No files matched your search

+2 -13
View File
@@ -14,21 +14,10 @@ body:
value: "An exception appeared"
validations:
required: true
- type: dropdown
- type: textarea
id: version
attributes:
label: Version
description: What version of our software are you running?
options:
- 0.0.17
- 0.0.16
- 0.0.15
- 0.0.14
- 0.0.13
- 0.0.11
- 0.0.10
- 0.0.9
default: 0
label: What version of our software are you running?
validations:
required: true
- type: textarea
+2
View File
@@ -17,6 +17,8 @@ After the installation, you can use this button to install the integration:
### Supported devices:
- AC60
- AC70 (basic data)
- AC70P (untested)
- AC180 (basic data)
- AC180P (basic data)
- AC200L (untested)
+32 -7
View File
@@ -97,6 +97,27 @@ class BluettiBinarySensor(CoordinatorEntity, BinarySensorEntity):
"""Return if entity is available."""
return self._attr_available
def _set_available(self):
"""Set sensor as available."""
self._attr_available = True
self._unavailable_counter = 0
self._attr_extra_state_attributes = {}
self.async_write_ha_state()
def _set_unavailable(self, cause: str = "Unknown"):
"""Set sensor as unavailable."""
self._unavailable_counter += 1
self._attr_extra_state_attributes = {
"unavailable_counter": self._unavailable_counter,
"unavailable_cause": cause,
}
if self._unavailable_counter >= 5:
self._attr_available = False
self.async_write_ha_state()
@callback
def _handle_coordinator_update(self) -> None:
"""Handle updated data from the coordinator."""
@@ -104,19 +125,24 @@ class BluettiBinarySensor(CoordinatorEntity, BinarySensorEntity):
if self.coordinator.reader.persistent_conn and not self.coordinator.reader.client.is_connected:
return
if self.coordinator.data is None:
_LOGGER.debug(
"Data from coordinator is None",
)
self._set_unavailable("Data is None")
return
_LOGGER.debug("Updating state of %s", unique_id_loggable(self._attr_unique_id))
if not isinstance(self.coordinator.data, dict):
_LOGGER.debug(
"Invalid data from coordinator (binary_sensor.%s)", unique_id_loggable(self._attr_unique_id)
)
self._attr_available = False
self.async_write_ha_state()
self._set_unavailable("Invalid data")
return
response_data = self.coordinator.data.get(self._response_key)
if response_data is None:
self._attr_available = False
self.async_write_ha_state()
self._set_unavailable("No data")
return
if not isinstance(response_data, bool):
@@ -125,10 +151,9 @@ class BluettiBinarySensor(CoordinatorEntity, BinarySensorEntity):
unique_id_loggable(self._attr_unique_id),
response_data,
)
self._attr_available = False
self.async_write_ha_state()
self._set_unavailable("Invalid data type")
return
self._attr_available = True
self._set_available()
self._attr_is_on = self.coordinator.data[self._response_key] is True
self.async_write_ha_state()
@@ -110,7 +110,12 @@ class DeviceReader:
await self._async_send_command(command)
)
_LOGGER.debug("Raw data set: %s", body)
# b'\x00\x02' b'\x00\x03' here (seems like result)
# Check set pack_num
set_pack = int.from_bytes(body, byteorder='big')
if set_pack is not pack:
_LOGGER.warning("Pack polling failed (pack_num %i doesn't match expected %i)", set_pack, pack)
continue
for command in pack_commands:
# Request & parse result for each pack
@@ -124,6 +129,8 @@ class DeviceReader:
_LOGGER.debug("Parsed data: %s", parsed)
for key, value in parsed.items():
# Ignore likely unavailable pack data
if value != 0:
parsed_data.update({key + str(pack): value})
except ParseError:
@@ -13,17 +13,17 @@ class AC200L(ProtocolV1Device):
# Details
self.struct.add_enum_field("ac_output_mode", 70, OutputMode)
self.struct.add_decimal_field("internal_ac_voltage", 71, 1)
self.struct.add_decimal_field("internal_ac_voltage", 71, 1, multiplier=10)
self.struct.add_decimal_field("internal_current_one", 72, 1)
self.struct.add_uint_field("internal_power_one", 73)
self.struct.add_decimal_field("internal_ac_frequency", 74, 2)
self.struct.add_uint_field("internal_dc_input_voltage", 86)
self.struct.add_decimal_field("internal_dc_input_power", 87, 1)
self.struct.add_decimal_field("internal_ac_frequency", 74, 2, multiplier=10)
self.struct.add_uint_field("internal_dc_input_voltage", 86, multiplier=.1)
self.struct.add_decimal_field("internal_dc_input_power", 87, 1, multiplier=10)
self.struct.add_decimal_field("internal_dc_input_current", 88, 2)
# Battery packs
self.struct.add_uint_field("pack_num_max", 91) # internal
self.struct.add_decimal_field("total_battery_voltage", 92, 1)
self.struct.add_decimal_field("total_battery_voltage", 92, 1, multiplier=.1)
self.struct.add_uint_field("pack_num_result", 96) # internal
self.struct.add_decimal_field("pack_voltage", 98, 2) # Full pack voltage
self.struct.add_uint_field("pack_battery_percent", 99)
@@ -0,0 +1,8 @@
"""AC70 fields."""
from ..base_devices.ProtocolV2Device import ProtocolV2Device
class AC70(ProtocolV2Device):
def __init__(self, address: str, sn: str):
super().__init__(address, "AC70", sn)
@@ -0,0 +1,8 @@
"""AC70P fields."""
from ..base_devices.ProtocolV2Device import ProtocolV2Device
class AC70P(ProtocolV2Device):
def __init__(self, address: str, sn: str):
super().__init__(address, "AC70P", sn)
@@ -3,6 +3,8 @@
import re
from ..devices.ac60 import AC60
from ..devices.ac70 import AC70
from ..devices.ac70p import AC70P
from ..devices.ac180 import AC180
from ..devices.ac180p import AC180P
from ..devices.ac200l import AC200L
@@ -17,7 +19,7 @@ from ..devices.ep760 import EP760
from ..devices.ep800 import EP800
DEVICE_NAME_RE = re.compile(
r"^(AC60|AC180|AC180P|AC200L|AC200M|AC300|AC500|EB3A|EP500|EP500P|EP600|EP760|EP800)(\d+)$"
r"^(AC60|AC70|AC70P|AC180|AC180P|AC200L|AC200M|AC300|AC500|EB3A|EP500|EP500P|EP600|EP760|EP800)(\d+)$"
)
@@ -25,6 +27,10 @@ def build_device(address: str, name: str):
match = DEVICE_NAME_RE.match(name)
if match[1] == "AC60":
return AC60(address, match[2])
if match[1] == "AC70":
return AC70(address, match[2])
if match[1] == "AC70P":
return AC70P(address, match[2])
if match[1] == "AC180":
return AC180(address, match[2])
if match[1] == "AC180P":
@@ -91,7 +91,7 @@ class DecimalField(DeviceField):
def parse(self, data: bytes) -> Decimal:
val = Decimal(struct.unpack("!H", data)[0])
return (val / 10 ** self.scale) * self.multiplier
return (val / 10 ** self.scale) * Decimal(self.multiplier)
def in_range(self, val: Decimal) -> bool:
if self.range is None:
+1 -1
View File
@@ -23,5 +23,5 @@
"iot_class": "local_polling",
"issue_tracker": "https://github.com/Patrick762/hassio-bluetti-bt/issues",
"requirements": [],
"version": "0.1.0"
"version": "0.1.2"
}
+27 -9
View File
@@ -114,6 +114,7 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
e_name = f"{device_info.get('name')} {name}"
self._address = address
self._response_key = response_key
self._unavailable_counter = 0
self._attr_device_info = device_info
self._attr_name = name
@@ -130,6 +131,27 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
"""Return if entity is available."""
return self._attr_available
def _set_available(self):
"""Set sensor as available."""
self._attr_available = True
self._unavailable_counter = 0
self._attr_extra_state_attributes = {}
self.async_write_ha_state()
def _set_unavailable(self, cause: str = "Unknown"):
"""Set sensor as unavailable."""
self._unavailable_counter += 1
self._attr_extra_state_attributes = {
"unavailable_counter": self._unavailable_counter,
"unavailable_cause": cause,
}
if self._unavailable_counter >= 5:
self._attr_available = False
self.async_write_ha_state()
@callback
def _handle_coordinator_update(self) -> None:
"""Handle updated data from the coordinator."""
@@ -141,8 +163,7 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
_LOGGER.debug(
"Data from coordinator is None",
)
self._attr_available = False
self.async_write_ha_state()
self._set_unavailable("Data is None")
return
_LOGGER.debug("Updating state of %s", unique_id_loggable(self._attr_unique_id))
@@ -150,15 +171,13 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
_LOGGER.warning(
"Invalid data from coordinator (sensor.%s)", unique_id_loggable(self._attr_unique_id)
)
self._attr_available = False
self.async_write_ha_state()
self._set_unavailable("Invalid data")
return
response_data = self.coordinator.data.get(self._response_key)
if response_data is None:
_LOGGER.debug("No data for available for (%s)", self._response_key)
self._attr_available = False
self.async_write_ha_state()
self._set_unavailable("No data")
return
if (
@@ -174,11 +193,10 @@ class BluettiSensor(CoordinatorEntity, SensorEntity):
response_data,
type(response_data),
)
self._attr_available = False
self.async_write_ha_state()
self._set_unavailable("Invalid data type")
return
self._attr_available = True
self._set_available()
# Different for enum and numeric
if (
+5
View File
@@ -0,0 +1,5 @@
homeassistant
bleak_retry_connector
pyserial
bluetooth_auto_recovery
crcmod
+18
View File
@@ -4,6 +4,8 @@ import unittest
from custom_components.bluetti_bt.bluetti_bt_lib.utils.device_builder import build_device
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac60 import AC60
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac70 import AC70
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac70p import AC70P
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac180 import AC180
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac180p import AC180P
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac200m import AC200M
@@ -32,6 +34,22 @@ class TestDeviceBuilder(unittest.TestCase):
self.assertIsInstance(built, AC60)
self.assertEqual(built.address, bt_addr)
def test_build_ac70(self):
bt_addr = "aa:bb:cc:dd:ee:ff"
bt_name = "AC7056786746478"
built = build_device(bt_addr, bt_name)
self.assertIsInstance(built, AC70)
self.assertEqual(built.address, bt_addr)
def test_build_ac70p(self):
bt_addr = "aa:bb:cc:dd:ee:ff"
bt_name = "AC70P56786746478"
built = build_device(bt_addr, bt_name)
self.assertIsInstance(built, AC70P)
self.assertEqual(built.address, bt_addr)
def test_build_ac180(self):
bt_addr = "aa:bb:cc:dd:ee:ff"
bt_name = "AC18056786746478"