"""EP600 fields."""
|
|
|
|
from typing import List
|
|
|
|
from ..utils.commands import ReadHoldingRegisters
|
|
from ..base_devices.ProtocolV2Device import ProtocolV2Device
|
|
|
|
|
|
class EP600(ProtocolV2Device):
|
|
def __init__(self, address: str, sn: str):
|
|
super().__init__(address, "EP600", sn)
|
|
|
|
# Details
|
|
self.struct.add_uint_field("battery_range_start", 2022)
|
|
self.struct.add_uint_field("battery_range_end", 2023)
|
|
self.struct.add_uint_field("max_ac_input_power", 2213)
|
|
self.struct.add_uint_field("max_ac_input_current", 2214)
|
|
self.struct.add_uint_field("max_ac_output_power", 2215)
|
|
self.struct.add_uint_field("max_ac_output_current", 2216)
|
|
|
|
# DC Solar
|
|
self.struct.add_uint_field("pv_input_power1", 1212)
|
|
self.struct.add_decimal_field("pv_input_voltage1", 1213, 1)
|
|
self.struct.add_decimal_field("pv_input_current1", 1214, 1)
|
|
self.struct.add_uint_field("pv_input_power2", 1220)
|
|
self.struct.add_decimal_field("pv_input_voltage2", 1221, 1)
|
|
self.struct.add_decimal_field("pv_input_current2", 1222, 1)
|
|
|
|
# ADL400 Smart Meter for AC Solar
|
|
self.struct.add_uint_field("adl400_ac_input_power_phase1", 1228)
|
|
self.struct.add_uint_field("adl400_ac_input_power_phase2", 1236)
|
|
self.struct.add_uint_field("adl400_ac_input_power_phase3", 1244)
|
|
self.struct.add_decimal_field("adl400_ac_input_voltage_phase1", 1229, 1)
|
|
self.struct.add_decimal_field("adl400_ac_input_voltage_phase2", 1237, 1)
|
|
self.struct.add_decimal_field("adl400_ac_input_voltage_phase3", 1245, 1)
|
|
# Testing required
|
|
self.struct.add_uint_field("adl400_ac_input_current_phase1", 1230)
|
|
self.struct.add_uint_field("adl400_ac_input_current_phase2", 1238)
|
|
self.struct.add_uint_field("adl400_ac_input_current_phase3", 1246)
|
|
|
|
# Grid Input
|
|
self.struct.add_decimal_field("grid_frequency", 1300, 1)
|
|
self.struct.add_uint_field("grid_power_phase1", 1313)
|
|
self.struct.add_uint_field("grid_power_phase2", 1319)
|
|
self.struct.add_uint_field("grid_power_phase3", 1325)
|
|
self.struct.add_decimal_field("grid_voltage_phase1", 1314, 1)
|
|
self.struct.add_decimal_field("grid_voltage_phase2", 1320, 1)
|
|
self.struct.add_decimal_field("grid_voltage_phase3", 1326, 1)
|
|
self.struct.add_decimal_field("grid_current_phase1", 1315, 1)
|
|
self.struct.add_decimal_field("grid_current_phase2", 1321, 1)
|
|
self.struct.add_decimal_field("grid_current_phase3", 1327, 1)
|
|
|
|
# EP600 AC Output
|
|
self.struct.add_decimal_field("ac_output_frequency", 1500, 1)
|
|
self.struct.add_int_field("ac_output_power_phase1", 1510)
|
|
self.struct.add_int_field("ac_output_power_phase2", 1517)
|
|
self.struct.add_int_field("ac_output_power_phase3", 1524)
|
|
self.struct.add_decimal_field("ac_output_voltage_phase1", 1511, 1)
|
|
self.struct.add_decimal_field("ac_output_voltage_phase2", 1518, 1)
|
|
self.struct.add_decimal_field("ac_output_voltage_phase3", 1525, 1)
|
|
self.struct.add_decimal_field("ac_output_current_phase1", 1512, 1)
|
|
self.struct.add_decimal_field("ac_output_current_phase2", 1519, 1)
|
|
self.struct.add_decimal_field("ac_output_current_phase3", 1526, 1)
|
|
|
|
# KM - Consumption
|
|
self.struct.add_int_field("consumption_power_phase1", 1430)
|
|
self.struct.add_int_field("consumption_power_phase2", 1436)
|
|
self.struct.add_int_field("consumption_power_phase3", 1442)
|
|
self.struct.add_decimal_field("consumption_voltage_phase1", 1431, 1)
|
|
self.struct.add_decimal_field("consumption_voltage_phase2", 1437, 1)
|
|
self.struct.add_decimal_field("consumption_voltage_phase3", 1443, 1)
|
|
self.struct.add_decimal_field("consumption_current_phase1", 1432, 1)
|
|
self.struct.add_decimal_field("consumption_current_phase2", 1438, 1)
|
|
self.struct.add_decimal_field("consumption_current_phase3", 1444, 1)
|
|
|
|
# KM - Totals
|
|
self.struct.add_uint_field('pv_input_power_all', 144) # Total PV in
|
|
self.struct.add_uint_field('consumption_power_all', 142) # Total AC out
|
|
self.struct.add_uint_field('grid_power_all', 146) # Total Grid in - value only +/- unknown
|
|
|
|
# Statistics
|
|
self.struct.add_decimal_field(
|
|
"total_ac_consumption", 152, 1
|
|
) # Load consumption
|
|
self.struct.add_decimal_field(
|
|
"total_grid_consumption", 156, 1
|
|
) # Grid consumption stats
|
|
self.struct.add_decimal_field("total_grid_feed", 158, 1)
|
|
|
|
# Battery packs
|
|
self.struct.add_swap_string_field("battery_type", 6101, 6) # internal
|
|
self.struct.add_sn_field("battery_serial_number", 6107) # internal
|
|
self.struct.add_version_field("bcu_version", 6175) # internal
|
|
self.struct.add_version_field("bmu_version", 6178) # internal
|
|
self.struct.add_version_field("safety_module_version", 6181) # internal
|
|
self.struct.add_version_field("high_voltage_module_version", 6184) # internal
|
|
|
|
@property
|
|
def polling_commands(self) -> List[ReadHoldingRegisters]:
|
|
return super().polling_commands + [
|
|
ReadHoldingRegisters(2022, 2),
|
|
ReadHoldingRegisters(2213, 5),
|
|
ReadHoldingRegisters(1212, 3),
|
|
ReadHoldingRegisters(1220, 3),
|
|
ReadHoldingRegisters(1228, 3),
|
|
ReadHoldingRegisters(1236, 3),
|
|
ReadHoldingRegisters(1244, 3),
|
|
ReadHoldingRegisters(1300, 1),
|
|
ReadHoldingRegisters(1313, 3),
|
|
ReadHoldingRegisters(1319, 3),
|
|
ReadHoldingRegisters(1325, 3),
|
|
ReadHoldingRegisters(1500, 1),
|
|
ReadHoldingRegisters(1510, 3),
|
|
ReadHoldingRegisters(1517, 3),
|
|
ReadHoldingRegisters(1524, 3),
|
|
ReadHoldingRegisters(152, 1),
|
|
ReadHoldingRegisters(156, 1),
|
|
ReadHoldingRegisters(158, 1),
|
|
# KM - Consumption
|
|
ReadHoldingRegisters(1430, 15),
|
|
# KM - Totals
|
|
ReadHoldingRegisters(142, 5),
|
|
|
|
]
|