Compare commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
9df2073585 | ||
|
|
2c6df77078 | ||
|
|
e584d32037 | ||
|
|
0cd5ae10fb | ||
|
|
a93b80796a | ||
|
|
a7967e74dd |
No files matched your search
@@ -69,7 +69,7 @@ class AC300(ProtocolV1Device):
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
range(3061, 3062),
|
||||
]
|
||||
|
||||
@property
|
||||
|
||||
@@ -68,7 +68,7 @@ class AC500(ProtocolV1Device):
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
range(3061, 3062),
|
||||
]
|
||||
|
||||
@property
|
||||
|
||||
@@ -64,7 +64,7 @@ class EP500(ProtocolV1Device):
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
range(3061, 3062),
|
||||
]
|
||||
|
||||
@property
|
||||
|
||||
@@ -64,7 +64,7 @@ class EP500P(ProtocolV1Device):
|
||||
def writable_ranges(self) -> List[range]:
|
||||
return super().writable_ranges + [
|
||||
range(3001, 3017),
|
||||
range(3061),
|
||||
range(3061, 3062),
|
||||
]
|
||||
|
||||
@property
|
||||
|
||||
@@ -62,6 +62,22 @@ class EP600(ProtocolV2Device):
|
||||
self.struct.add_decimal_field("ac_output_current_phase2", 1519, 1)
|
||||
self.struct.add_decimal_field("ac_output_current_phase3", 1526, 1)
|
||||
|
||||
# KM - Consumption
|
||||
self.struct.add_int_field("consumption_power_phase1", 1430)
|
||||
self.struct.add_int_field("consumption_power_phase2", 1436)
|
||||
self.struct.add_int_field("consumption_power_phase3", 1442)
|
||||
self.struct.add_decimal_field("consumption_voltage_phase1", 1431, 1)
|
||||
self.struct.add_decimal_field("consumption_voltage_phase2", 1437, 1)
|
||||
self.struct.add_decimal_field("consumption_voltage_phase3", 1443, 1)
|
||||
self.struct.add_decimal_field("consumption_current_phase1", 1432, 1)
|
||||
self.struct.add_decimal_field("consumption_current_phase2", 1438, 1)
|
||||
self.struct.add_decimal_field("consumption_current_phase3", 1444, 1)
|
||||
|
||||
# KM - Totals
|
||||
self.struct.add_uint_field('pv_input_power_all', 144) # Total PV in
|
||||
self.struct.add_uint_field('consumption_power_all', 142) # Total AC out
|
||||
self.struct.add_uint_field('grid_power_all', 146) # Total Grid in - value only +/- unknown
|
||||
|
||||
# Statistics
|
||||
self.struct.add_decimal_field(
|
||||
"total_ac_consumption", 152, 1
|
||||
@@ -100,4 +116,9 @@ class EP600(ProtocolV2Device):
|
||||
ReadHoldingRegisters(152, 1),
|
||||
ReadHoldingRegisters(156, 1),
|
||||
ReadHoldingRegisters(158, 1),
|
||||
# KM - Consumption
|
||||
ReadHoldingRegisters(1430, 15),
|
||||
# KM - Totals
|
||||
ReadHoldingRegisters(142, 5),
|
||||
|
||||
]
|
||||
@@ -217,6 +217,26 @@ FIELD_ATTRIBUTES: dict[str, FieldAttributes] = {
|
||||
"total_ac_consumption": EnergyFieldAttributes("Total Load Consumption"),
|
||||
"total_grid_consumption": EnergyFieldAttributes("Total Grid Consumption"),
|
||||
"total_grid_feed": EnergyFieldAttributes("Total Grid Feed"),
|
||||
|
||||
# KM - Consumption
|
||||
"consumption_power_phase1": PowerFieldAttributes("Consumption Power Phase 1"),
|
||||
"consumption_power_phase2": PowerFieldAttributes("Consumption Power Phase 2"),
|
||||
"consumption_power_phase3": PowerFieldAttributes("Consumption Power Phase 3"),
|
||||
"consumption_voltage_phase1": VoltageFieldAttributes("Consumption Voltage Phase 1"),
|
||||
"consumption_voltage_phase2": VoltageFieldAttributes("Consumption Voltage Phase 2"),
|
||||
"consumption_voltage_phase3": VoltageFieldAttributes("Consumption Voltage Phase 3"),
|
||||
"consumption_current_phase1": CurrentFieldAttributes("Consumption Current Phase 1"),
|
||||
"consumption_current_phase2": CurrentFieldAttributes("Consumption Current Phase 2"),
|
||||
"consumption_current_phase3": CurrentFieldAttributes("Consumption Current Phase 3"),
|
||||
# KM - Consumption end
|
||||
|
||||
# KM - Totals
|
||||
"pv_input_power_all": PowerFieldAttributes("PV Input Power All"),
|
||||
"consumption_power_all": PowerFieldAttributes("Consumption Power All"),
|
||||
"grid_power_all": PowerFieldAttributes("Grid Power All"),
|
||||
# KM - Totals end
|
||||
|
||||
|
||||
# Device specific controls
|
||||
"power_off": FieldAttributes(
|
||||
type=FieldType.BOOL,
|
||||
|
||||
@@ -23,5 +23,5 @@
|
||||
"iot_class": "local_polling",
|
||||
"issue_tracker": "https://github.com/Patrick762/hassio-bluetti-bt/issues",
|
||||
"requirements": [],
|
||||
"version": "0.0.22"
|
||||
"version": "0.0.23"
|
||||
}
|
||||
Reference in new issue
Block a user