Compare commits

...
19 Commits
Author SHA1 Message Date
Patrick762 6f9afedfdb Merge pull request #119 from kvanonavk/main
AC180P Advanced Integration
2024-07-19 16:17:16 +02:00
Patrick762 fe23dd00cd Merge pull request #122 from Patrick762/ac70-fix
Added ac70 auto detection
2024-07-19 16:13:48 +02:00
Patrick762 566761dba7 update version 2024-07-19 16:13:19 +02:00
Patrick762 33cb6e6fbd added ac70 auto detection 2024-07-19 15:02:57 +02:00
kvanonavk 5823136280 Merge branch 'Patrick762:main' into main 2024-07-05 14:44:12 +03:00
kvanonavk 7b6f845edb fixes 2024-07-05 14:42:56 +03:00
kvanonavk 1fbcf83b1b simple set charging mode (no turbo) 2024-07-01 18:16:58 +03:00
Patrick762 149633f9c8 Increase version number 2024-06-30 15:04:23 +02:00
Patrick762 9ab7cefda7 Merge pull request #116 from matthewpucc/main
Support AC70 and AC70P Device
2024-06-30 15:03:35 +02:00
Patrick762 52853d6d3e Merge pull request #117 from rotx/fix-multiply
Fix multiplication of Decimal with float
2024-06-30 15:03:14 +02:00
kvanonavk c96f551024 fixes 2024-06-30 14:11:31 +03:00
kvanonavk 75209ee1aa readme fix 2 2024-06-30 13:59:45 +03:00
kvanonavk 7396616113 readme fix 2024-06-30 13:56:58 +03:00
kvanonavk a7f7ff1843 fixes 2024-06-30 13:55:10 +03:00
kvanonavk cc755b3003 test + fix 2024-06-30 13:25:39 +03:00
kvanonavk e5f690ef3b AC180P more data and functionality 2024-06-30 12:24:52 +03:00
Robert Muchsel 3d3401c942 Fix multiplication of Decimal with float 2024-06-21 20:52:48 -05:00
Matthew Puccerella f50232ee89 Merge pull request #1 from matthewpucc/support_ac70_devices
Add support AC70 and AC70P devices
2024-06-20 16:12:53 -07:00
Matthew Puccerella 5922362772 Add support AC70 and AC70P devices 2024-06-20 23:11:47 +00:00
11 changed files with 111 additions and 5 deletions

No files matched your search

+3 -1
View File
@@ -17,8 +17,10 @@ After the installation, you can use this button to install the integration:
### Supported devices:
- AC60
- AC70 (basic data)
- AC70P (untested)
- AC180 (basic data)
- AC180P (basic data)
- AC180P (tested)
- AC200L (untested)
- AC200M
- AC300 (tested)
@@ -1,8 +1,52 @@
"""AC180P fields."""
from ..base_devices.ProtocolV2Device import ProtocolV2Device
from typing import List
from ..field_enums import ChargingMode
from ..utils.commands import ReadHoldingRegisters
from ..base_devices.ProtocolV2Device import ProtocolV2Device
class AC180P(ProtocolV2Device):
def __init__(self, address: str, sn: str):
super().__init__(address, "AC180P", sn)
# Power IO
self.struct.add_uint_field('dc_output_power', 140)
self.struct.add_uint_field('ac_output_power', 142)
self.struct.add_uint_field('dc_input_power', 144)
self.struct.add_uint_field('ac_input_power', 146)
# Input Details (1100 - 1300)
self.struct.add_decimal_field('ac_input_voltage', 1314, 1)
# Controls (2000)
self.struct.add_bool_field('ac_output_on_switch', 2011)
self.struct.add_bool_field('dc_output_on_switch', 2012)
self.struct.add_bool_field('silent_charging_on', 2020) # to be able to choose between normal and silent charging modes
self.struct.add_enum_field('charging_mode', 2020, ChargingMode) # can't be set from HA, custom switch needed
self.struct.add_bool_field('power_lifting_on', 2021)
# Controls (2200)
self.struct.add_bool_field('grid_enhancement_mode_on', 2225)
@property
def polling_commands(self) -> List[ReadHoldingRegisters]:
return super().polling_commands + [
ReadHoldingRegisters(140, 1),
ReadHoldingRegisters(142, 1),
ReadHoldingRegisters(144, 1),
ReadHoldingRegisters(146, 1),
ReadHoldingRegisters(1314, 1),
ReadHoldingRegisters(2011, 1),
ReadHoldingRegisters(2012, 1),
ReadHoldingRegisters(2020, 1),
ReadHoldingRegisters(2021, 1),
ReadHoldingRegisters(2225, 1),
]
@property
def writable_ranges(self) -> List[range]:
return super().writable_ranges + [
range(2000, 2022),
range(2200, 2226)
]
@@ -0,0 +1,8 @@
"""AC70 fields."""
from ..base_devices.ProtocolV2Device import ProtocolV2Device
class AC70(ProtocolV2Device):
def __init__(self, address: str, sn: str):
super().__init__(address, "AC70", sn)
@@ -0,0 +1,8 @@
"""AC70P fields."""
from ..base_devices.ProtocolV2Device import ProtocolV2Device
class AC70P(ProtocolV2Device):
def __init__(self, address: str, sn: str):
super().__init__(address, "AC70P", sn)
@@ -316,6 +316,16 @@ FIELD_ATTRIBUTES: dict[str, FieldAttributes] = {
setter=True,
name="Power Lifting",
),
"grid_enhancement_mode_on": FieldAttributes(
type=FieldType.BOOL,
setter=True,
name="Grid Enhancement Mode",
),
"silent_charging_on": FieldAttributes(
type=FieldType.BOOL,
setter=True,
name="Silent Charging",
),
}
@@ -3,6 +3,8 @@
import re
from ..devices.ac60 import AC60
from ..devices.ac70 import AC70
from ..devices.ac70p import AC70P
from ..devices.ac180 import AC180
from ..devices.ac180p import AC180P
from ..devices.ac200l import AC200L
@@ -17,7 +19,7 @@ from ..devices.ep760 import EP760
from ..devices.ep800 import EP800
DEVICE_NAME_RE = re.compile(
r"^(AC60|AC180|AC180P|AC200L|AC200M|AC300|AC500|EB3A|EP500|EP500P|EP600|EP760|EP800)(\d+)$"
r"^(AC60|AC70|AC70P|AC180|AC180P|AC200L|AC200M|AC300|AC500|EB3A|EP500|EP500P|EP600|EP760|EP800)(\d+)$"
)
@@ -25,6 +27,10 @@ def build_device(address: str, name: str):
match = DEVICE_NAME_RE.match(name)
if match[1] == "AC60":
return AC60(address, match[2])
if match[1] == "AC70":
return AC70(address, match[2])
if match[1] == "AC70P":
return AC70P(address, match[2])
if match[1] == "AC180":
return AC180(address, match[2])
if match[1] == "AC180P":
@@ -91,7 +91,7 @@ class DecimalField(DeviceField):
def parse(self, data: bytes) -> Decimal:
val = Decimal(struct.unpack("!H", data)[0])
return (val / 10 ** self.scale) * self.multiplier
return (val / 10 ** self.scale) * Decimal(self.multiplier)
def in_range(self, val: Decimal) -> bool:
if self.range is None:
+4
View File
@@ -23,6 +23,7 @@ SUPPORTED_MODELS = [
"EP500P",
"EP600",
"EP760",
"AC180P",
]
CONTROL_FIELDS = [
@@ -31,6 +32,8 @@ CONTROL_FIELDS = [
"power_off",
"eco_on",
"power_lifting_on",
"grid_enhancement_mode_on",
"silent_charging_on",
]
DIAGNOSTIC_FIELDS = [
@@ -45,4 +48,5 @@ DIAGNOSTIC_FIELDS = [
"total_ac_consumption",
"total_grid_consumption",
"total_grid_feed",
"ac_input_voltage",
]
+2 -1
View File
@@ -3,6 +3,7 @@
"name": "Bluetti BT",
"bluetooth": [
{ "local_name": "AC60*" },
{ "local_name": "AC70*" },
{ "local_name": "AC180*" },
{ "local_name": "AC200L*" },
{ "local_name": "AC200M*" },
@@ -23,5 +24,5 @@
"iot_class": "local_polling",
"issue_tracker": "https://github.com/Patrick762/hassio-bluetti-bt/issues",
"requirements": [],
"version": "0.1.1"
"version": "0.1.3"
}
+5
View File
@@ -0,0 +1,5 @@
homeassistant
bleak_retry_connector
pyserial
bluetooth_auto_recovery
crcmod
+18
View File
@@ -4,6 +4,8 @@ import unittest
from custom_components.bluetti_bt.bluetti_bt_lib.utils.device_builder import build_device
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac60 import AC60
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac70 import AC70
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac70p import AC70P
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac180 import AC180
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac180p import AC180P
from custom_components.bluetti_bt.bluetti_bt_lib.devices.ac200m import AC200M
@@ -32,6 +34,22 @@ class TestDeviceBuilder(unittest.TestCase):
self.assertIsInstance(built, AC60)
self.assertEqual(built.address, bt_addr)
def test_build_ac70(self):
bt_addr = "aa:bb:cc:dd:ee:ff"
bt_name = "AC7056786746478"
built = build_device(bt_addr, bt_name)
self.assertIsInstance(built, AC70)
self.assertEqual(built.address, bt_addr)
def test_build_ac70p(self):
bt_addr = "aa:bb:cc:dd:ee:ff"
bt_name = "AC70P56786746478"
built = build_device(bt_addr, bt_name)
self.assertIsInstance(built, AC70P)
self.assertEqual(built.address, bt_addr)
def test_build_ac180(self):
bt_addr = "aa:bb:cc:dd:ee:ff"
bt_name = "AC18056786746478"